Influence of air humidity and the distance from the source on negative air ion concentration in indoor air.

نویسندگان

  • Chih Cheng Wu
  • Grace W M Lee
  • Shinhao Yang
  • Kuo-Pin Yu
  • Chia Ling Lou
چکیده

Although negative air ionizer is commonly used for indoor air cleaning, few studies examine the concentration gradient of negative air ion (NAI) in indoor environments. This study investigated the concentration gradient of NAI at various relative humidities and distances form the source in indoor air. The NAI was generated by single-electrode negative electric discharge; the discharge was kept at dark discharge and 30.0 kV. The NAI concentrations were measured at various distances (10-900 cm) from the discharge electrode in order to identify the distribution of NAI in an indoor environment. The profile of NAI concentration was monitored at different relative humidities (38.1-73.6% RH) and room temperatures (25.2+/-1.4 degrees C). Experimental results indicate that the influence of relative humidity on the concentration gradient of NAI was complicated. There were four trends for the relationship between NAI concentration and relative humidity at different distances from the discharge electrode. The changes of NAI concentration with an increase in relative humidity at different distances were quite steady (10-30 cm), strongly declining (70-360 cm), approaching stability (420-450 cm) and moderately increasing (560-900 cm). Additionally, the regression analysis of NAI concentrations and distances from the discharge electrode indicated a logarithmic linear (log-linear) relationship; the distance of log-linear tendency (lambda) decreased with an increase in relative humidity such that the log-linear distance of 38.1% RH was 2.9 times that of 73.6% RH. Moreover, an empirical curve fit based on this study for the concentration gradient of NAI generated by negative electric discharge in indoor air was developed for estimating the NAI concentration at different relative humidities and distances from the source of electric discharge.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing Indoor Air Pollution within Different Areas of Female Beauty Centers and Exploring Their Relation to Various Respiratory Symptoms

The staff working at beauty centers are exposed to various chemicalproducts used daily in their working environment. Both hair dressers and nail techniciansare exposed to chemicals that are known to have an influence on the respiratory system.In order to evaluate such influence, this cross-sectional observational study wasconducted on a randomly selected 14 beauty centers in Dammam City, Saudi ...

متن کامل

Indoor particulate concentration during biomass burning in central India

Indoor air particulate (PM) exposure is several folds more dangerous than  outdoor air  owing to burning of different materials. Burning biomass emits toxic fumes that are found to be associated with  numerous health problems  such as respiratory diseases, etc. In our study area,  approximately 80% of the population of Chhattisgarh state, central India use biomass  such as wood, and cow dung as...

متن کامل

Assessing Indoor Air Pollution within Different Areas of Female Beauty Centers and Exploring Their Relation to Various Respiratory Symptoms

The staff working at beauty centers are exposed to various chemicalproducts used daily in their working environment. Both hair dressers and nail techniciansare exposed to chemicals that are known to have an influence on the respiratory system.In order to evaluate such influence, this cross-sectional observational study wasconducted on a randomly selected 14 beauty centers in Dammam City, Saudi ...

متن کامل

Study of Dioxide Carbon Concentration and Indoor Air Quality in Some Buildings in the Equatorial Region of Cameroon (Yaounde)

Background and purpose: Elevated CO2 rate in a building affect the health of occupant. This document presents results of an experimental analysis conducted in 50 offices located in 12 buildings with different layer in Cameroon (Yaounde). This study took place in 2012, during the dry and the rainy seasons. The main goal is to show the influence of the building structure, the ventilation and the ...

متن کامل

Evaluation of cooking emitted particulate matter concentration and workers cancer risk assessment in the sari fast-food shops

Introduction: One of the harmful pollutants in the indoor environments is particulate matters. Particles smaller than 2.5 micrometer in diameter that are suspend in the industrial environments air are the most deleterious dusts which can cause lung disease and cancer. In present study PM2.5 concentration in the fast-food shops air and its cancer risk for shop workers were assessed.   Material ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 370 1  شماره 

صفحات  -

تاریخ انتشار 2006