ROM Plus®: accurate point-of-care detection of ruptured fetal membranes

نویسندگان

  • Ross W McQuivey
  • Jon E Block
چکیده

Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

OBJECTIVE Accurate and timely diagnosis of rupture of membranes (ROM) is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. METHODS Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal...

متن کامل

ActimTMPROM, AmniSure®, and ROM +plus®: Rupture of membrane kits tested on amniotic fluid from women at C-section: a comparative study

Objectives: To confirm three point of care commercial tests for rupture of membranes consistently and accurately detect amniotic fluids from pregnant women, and they are practical and easy to use. Methods: Samples of fresh amniotic fluid were collected in a syringe taken at time of Csection and run on kits (ActimTMPROM, AmniSure®, and ROM +plus®) from three commercially available point of care ...

متن کامل

Comparison of rapid immunoassays for rupture of fetal membranes

BACKGROUND Rupture of membranes (ROM) before the onset of uterine contractions, particularly in pregnancies less than 37 weeks gestational age, is a common diagnostic problem in obstetrical practice. Timely detection of ROM is vital to support gestational age-specific interventions to optimize perinatal outcomes and minimize the risk of serious complications such as preterm delivery, fetal dist...

متن کامل

Comment on: Guidelines for the management of spontaneous preterm labor: identification of spontaneous preterm labor, diagnosis of preterm premature rupture of membranes and preventive tools for preterm birth

With great interest I read the recently published guidelines for the management of spontaneous preterm labor [1]. I was delighted to see that unlike the previous guidelines published in 2006 [2], these new ones also take into consideration the diagnostic marker insulin-like growth factor binding protein-1 (IGFBP-1) that I have worked with since the early 80s. However, I would like to bring the ...

متن کامل

Weakening and Rupture of Human Fetal Membranes – Biochemistry and Biomechanics

In spite of advances in the quality of prenatal care, management of high-risk pregnancies and treatment strategies targeting prevention of preterm births, the rate of preterm births in the US has continued to rise over the last two decades and is associated with high mortality and morbidity. Care of preterm infants also poses a significant financial burden on limited health care resources. Infa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016