External Insulation Design of Converter Stations for Xiangjiaba - Shanghai ± 800 kV UHVDC Project

نویسندگان

  • Liying Gao
  • Weimin Ma
چکیده

-External insulation is one of the critical aspects in the HVDC equipments and converter station design. Especially for UHVDC converter stations, the long creepage and clearance required has significant impact on the equipment and station design. The external insulation design of DC yard, valve hall, and for converter valves is presented. It is the intention of this report to review and summarize the work that has been done and the decisions that have been taken to the benefit of further work and design of new projects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technology and Development of 800 kV HVDC Applications

Bulk Power HVDC transmission schemes over distances of up to 2000 km are currently under planning for various large hydropower stations in India and China. Ultra high dc voltage (UHVDC) up to 800 kV is the preferred dc voltage level for these applications. Currently world-wide existing HVDC schemes are limited to maximum voltage levels of 500 kV to 600 kV. Therefore, the impact of increased ste...

متن کامل

Alternative Methods for Testing the Pole-to-ground Insulation of Thyristor Valves in Uhvdc Systems

In the design of DC system, more than one MVU tower may be used between pole-to-neutral voltages. This is especially common for UHVDC systems. The insulation design of these MVU’s need to be verified by dielectric type tests as specified by international standards. However, the application of several MVU’s in series makes the test set-up complicated. One straightforward solution is to install a...

متن کامل

An Improved Commutation Prediction Algorithm to Mitigate Commutation Failure in High Voltage Direct Current

Commutation failure is a common fault for line-commutated converters in the inverter. To reduce the possibility of commutation failure, many prediction algorithms based on alternating current (AC) voltage detection have already been implemented in high voltage direct current (HVDC) control and protection systems. Nevertheless, there are currently no effective methods to prevent commutation fail...

متن کامل

Electrostatic Field Analysis of 1200 Kv Testing Transformer by Boundary Element Method

Design of a 1200 kV power transformer is a real challenge for designer from dielectric point of view. It is possible to design a more compact transformer meeting even higher insulation levels with lesser insulation content. This has been possible with the introduction of sophisticated Computer-Aided Electrostatic Field Analysis. Analysis of the Lead Exit assembly of 1200 kV HV is presented. Two...

متن کامل

Analysis and Design of a New Single Switch Non-Isolated Buck-Boost dc-dc Converter

In this paper, a new transformerless buck-boost converter based on ZETA converter is introduced. The proposed converter has the ZETA converter advantages such as, buck-boost capability and input to output DC insulation. The suggested converter voltage gain is higher than the classic ZETA converter. In the presented converter, only one main switch is utilized. The proposed converter offers low v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010