WE-G-BRB-02: MU-EPID an EPID Based Tool for IMRT Quality Assurance.

نویسندگان

  • L Vazquez Quino
  • S Stathakis
  • A Gutierrez
  • C Esquivel
  • H Alkhatib
  • N Papanikolaou
چکیده

PURPOSE A software program (MU-EPID) has been developed to perform patient specific IMRT pre-treatment QA verification using an electronic portal imaging device. METHODS The software converts measured images of intensity modulated beams delivered to an EPID, into fluence maps that can be imported in the treatment planning system. The dose can then be calculated in the patient anatomy and compared against the patient's treatment plan for QA purposes. We first benchmarked the software using as a patient a cylindrical phantom. An aSi-1000 EPID mounted on a Varian Novalis linear accelerator was used for the image acquisition. Finally, IMRT plans from different treatment sites were used to further validate this in- house software. QA analysis was performed by evaluation of isodose distributions, DVH comparison and 2D gamma analysis. RESULTS The validation study with the cylindrical phantom showed that the dose to the ion chamber measurement point was in good agreement with both the original treatment plan and the MU-EPID reconstructed dose. Similar results were found for the clinical cases that we studied. A gamma analysis of the dose to the isocenter plane was performed for each plan. Using 3% and 3 mm as the evaluation criteria, resulted in an average of 97.44% of pixels passing the analysis (gamma<1). Good agreement was also observed for the DVH, isodose and profile comparisons between the clinically delivered IMRT plan and the MU-EPID derived dose calculation. CONCLUSIONS The results of the present investigation suggest that MU-EPID can be used in a clinical environment and can be used for patient specific QA for IMRT plans. This work has been supported by the SCOA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Streamlining EPID-based IMRT quality assurance: auto-analysis and auto-report generation

Using an EPID for patient specific IMRT QA is an efficient way to verify patient plans prior to the treatment. Our centres’ current EPID dosimetry method is based on a water equivalent depth approach, where EPID images of each IMRT field are converted to dose images and compared to Treatment planning system calculated dose images using a commercial software tool. Two physicists across two sites...

متن کامل

EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams

We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Dose calibration of EPIDs for segmented IMRT dosimetry

The purpose of this study was to investigate the dose response of amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) under different acquisi- tion settings for both open jaw defined fields and segmented intensity-modulated radiation therapy (IMRT) fields. Four different EPIDs were used. Two Siemens and one Elekta plus a standalone Perkin Elmer research EPID. Each was operated wi...

متن کامل

Performance Evaluation of the Siemens Electronic Portal Imaging Device for IMRT Plan Verification

A commercially available amorphous Silicon Electronic Portal imaging device (aSi-EPID) installed onto Siemens Oncor Linear accelerator was evaluated with the objective to be implemented for IMRT quality assurance. EPID properties were investigated; these include reproducibility, dependences between the relative EPID responses and field size, dose rate were studied for both photon beams. To dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part28  شماره 

صفحات  -

تاریخ انتشار 2012