Osteosynthesis using plates and screws after removing a limited area of the periosteum in order to reduce misclassified during radiological assessment metacarpal shaft fractures

نویسندگان

  • Neagu TP
  • Popescu SA
  • Cobilinschi C
  • Tincu R
  • Tiglis M
  • Lascar I
چکیده

Hand fractures are one of the most common causes for presenting to the emergency room. Metacarpal fractures count about 18 to 44% of all hand fractures, and are most often standalone closed injuries, without misplacement, not needing operative treatment. We present a case in which osteosynthesis with plates and screws was used to reduce two metacarpal fractures in order to allow an early motion recovery, despite the fact that a small portion of the periosteum needed to be removed. The type of fractures were misclassified according to the radiological findings, therefore the correct diagnosis was established during surgery. The results according to the radiological aspects and to the DASH score were excellent with 95% function recovery at twelve months. In this case, the use of osteosynthesis with plates and screws led to a good fracture healing without any major complications. However, there are a series of complications related to this method that should be taken into consideration. Being misled by the radiological aspects of the fractures, the most certain way to classify a metacarpal shaft fracture is through exploratory surgery, even if in most of the cases the three radiological views are enough to establish the diagnosis. Abbreviations: DASH score = Disability of Arm, Shoulder and Hand score, TAM = Total Active Motion, MCP = metacarpal phalangeal joint, PIP = proximal inter phalangeal joint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic plate osteosynthesis for fracture stabilization: how to do it

Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent...

متن کامل

Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up

Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...

متن کامل

Multifragmentary Tibial Pilon Fractures: Midterm Results After Osteosynthesis with External Fixation and Multiple Lag Screws

Osteosynthesis of intraarticular tibial pilon fractures is preferably achieved using locking plates via a minimally invasive technique. If combined with severe soft tissue damage there is a high risk of wound-healing deficits after plate osteosynthesis. Thus our aim was to find an alternative method of treatment for those cases with combined soft tissue injuries.We report on five cases with com...

متن کامل

A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test

In the published literature there are controversial data to the biomechanical stability of monocortical comparing to the bicortical fixation of metacarpal fractures. The aim of this study was to compare the biomechanical stability of monocortical and bicortical locking osteosynthesis in quasi-static and dynamic 4-point bending tests of composite third metacarpal bone (4th Gen third metacarpal, ...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016