From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity.

نویسندگان

  • Sjoerd Crijns
  • Bas Raaymakers
چکیده

Recently, the MRI-linac prototype at UMC Utrecht was upgraded with a ring-based gantry, where all linac components are mounted on a ring around the MR scanner. Although adaptations have been made to both linac and MR magnets in order to account for mutual magnetic interference, interference problems cannot be ruled out completely. Therefore, in this paper the impact of gantry position dependent magnetic field inhomogeneity variation on the geometrical accuracy of acquired MR images is quantified. Magnetic field maps were acquired in a large field of view for static gantry positions in shimmed and un-shimmed conditions. Reproducibility of the shim settings was assessed. From the fieldmaps, a minimum gradient strength needed to acquire images with geometric distortions of, at most, 1 mm was derived. Moreover, imaging during gantry rotation was performed for a range of imaging parameters and rotation speeds. From the measurements we conclude that images with good geometric fidelity can be obtained for all static gantry positions, provided that shimming is performed for each new gantry position. This indicates that the present prototype is suitable for static IMRT scenarios. Shim settings are highly reproducible, suggesting that shimming via look-up tables is feasible. Finally, imaging during gantry rotation may produce severely distorted images at present and is likely to require advanced compensation methods such as dynamic shimming or higher order reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system.

The authors report the first magnetic resonance (MR) images produced by their prototype MR system integrated with a radiation therapy source. The prototype consists of a 6 MV linac mounted onto the open end of a biplanar 0.2 T permanent MR system which has 27.9 cm pole-to-pole opening with flat gradients (40 mT/m) running under a TMX NRC console. The distance from the magnet isocenter to the li...

متن کامل

Impact of backscattered radiation from the bunker structure on EPID dosimetry

Amorphous silicon electronic portal imaging devices (EPIDs) have been investigated and used for dosimetry in radiotherapy for several years. The presence of a phosphor scintillator layer in the structure of these EPIDs has made them sensitive to low-energy scattered and backscattered radiation. In this study, the backscattered radiation from the walls, ceiling, and floor of a linac bunker has b...

متن کامل

بررسی میزان مواجهه شغلی با میدان های مغناطیسی پایا واثرات بهداشتی آن در مراکز تصویر برداری تشدید مغناطیسی

 Background and aim:  Magnetic resonance imaging as one of the best medical scanning technique is considered to be the most important sources of static magnetic fields. The staffs of MRI ´s units frequently exposed to these static magnetic fields. This study aims to determine the occupational exposure level to mentioned field and its related health effects in MRI´s units.    Methods:  The occup...

متن کامل

Dosimetric Effect Resulting From the Collimator Angle, the Isocenter Move, and the Gantry Angle Errors

Introduction: Dose distribution can be affected by diverse parameters, such as beam orientations, and collimator angles. These parameters should respect and maintain the international recommended levels during the realization of the quality assurance protocols of linear accelerators. This study aimed at evaluating the dosimetric effects on treatment quality considering...

متن کامل

Development of a prototype stereotactic collimation assembly for Neptun 10 PC linac

Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 59 13  شماره 

صفحات  -

تاریخ انتشار 2014