Clinical importance of the lens opacities classification system III (LOCS III) in phacoemulsification.

نویسندگان

  • Goran Bencić
  • Mia Zorić-Geber
  • Dean Sarić
  • Maja Corak
  • Zdravko Mandić
چکیده

The aim of this study was to compare the correlation of features of cataracts graded by the Lens Opacities Classification System, version III (LOCS III) with recorded operative characteristics during the phacoemulsification. The retrospective study included 245 cases operated on by a single surgeon from October 2003 to March 2004. The cataract was graded at the biomicroscope using the 4 grading scales of the lens opacities classification system, version III (LOCS III); nuclear opalescence (NO), nuclear color (CO), cortical cataract (C) and posterior subcapsular cataract (P). We recorded 2 intraoperative characteristics: machine measured phacoemulsification time, and average machine power. The machine recorded phacoemulsification time and average power correlated positively with the estimated nuclear color (NC) scale and nuclear opaclescence (NO) scale. Grading within categories of cortical cataract (C) and posterior subcapsular cataract (P) did not correlate with any of the operative variables. Exponentially, greater phacoemulsification energy was required as NC and NO increased. LOCS III grading system enables the surgeon to anticipate potential pitfalls and to adapt the operative technique to the individual patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.

PURPOSE To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to...

متن کامل

Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale

PURPOSE To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). METHODS Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus we...

متن کامل

Effect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery.

PURPOSE To compare the effect of different fragmentation softening grids in femtosecond laser-assisted cataract surgery on effective phacoemulsification time (EPT). SETTING Ruhr University Eye Clinic, Bochum, Germany. DESIGN Prospective randomized clinical trial. METHODS The study evaluated the feasibility of using a femtosecond laser (Catalys Precision Laser System) to perform capsulotom...

متن کامل

Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT) with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT) with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III) lens grading and corrected distance visual acuity (BCVA). Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were a...

متن کامل

A Comparison of the Efficacy of Cataract Surgery Using Aqualase® with Phacoemulsification Using MicroFlow® System

PURPOSE To compare the outcomes after phacoemulsification performed with the AquaLase and phacoemulsification in MicroFlow system, including surgically induced astigmatism (SIA), corneal endothelial cell damage and postoperative recovery of visual acuity. METHODS The cataracts of Lens Opacities Classification System, version III (LOCS III) nuclear grade below 2 were subjected in this study. N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 29 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2005