The size-tuning of the face-distortion after-effect
نویسندگان
چکیده
Recently, Webster and MacLin demonstrated a face-distortion after-effect (FDAE) for both upright and inverted faces: adaptation to a distorted face makes a normal face appear distorted in the direction opposite to the adapting direction. Neurophysiological studies (e.g. Experimental Brain Research 65 (1986) 38) show that face-selective neurons in the superior temporal sulcus (STS) are remarkably size-invariant in their responses. If the site of adaptation underlying the FDAE is the homologous neuron population in human vision, then the FDAE should also be highly tolerant to changes in size between adapting and test faces. Here, we test this prediction. Observers were adapted to distorted upright/inverted faces of three different sizes (3.3 degrees x 3.7 degrees, 6.6 degrees x 7.5 degrees, and 13.1 degrees x 14.8 degrees ). For adapting faces of all three sizes, observers adjusted test faces of all three sizes until they appeared normal. Significant FDAEs were observed in all conditions. For both upright and inverted faces, FDAEs were approximately twice as strong when adapting and test faces were the same size than when they differed by even a single octave in size. The magnitudes of FDAEs were comparable for upright and inverted faces. The larger FDAEs for same-size adapting and test faces suggest that part of the FDAE derives from a neuron population with narrow size-tuning. However, the significant FDAEs obtained for adapting and test images differing by two octaves implicate a different neuron population with broad size-tuning, possibly the human homolog of the face-selective neuron population in monkey STS.
منابع مشابه
Effect of 12-week corrective exercises on postural sways in male students with pronation distortion syndrome
Pronation distortion syndrome is one of the most common abnormalities in the body that causes distortions in the structures of the skeletal structures of the lower extremities and increases postural sways. The purpose of this study was to determine the effect of 12-week corrective exercises on postural sways in male students with pronation distortion syndrome. In this semi experimental research...
متن کاملThe effect of activated flux type on the weld profile and angular distortion of A-TIG welding of the AISI 2205 duplex stainless steel
In this investigation, the AISI 2205 duplex stainless steel was welded in the form of bead on plate by A-TIG process with different amount of the ZrO2 and TiO2 activated fluxes. The results of the visual inspection showed that the specimen with 50% ZrO2 and 50% TiO2 activated flux, had the lowest face width and the specimen with contains 90% ZrO2 activated flux, had the highest penetration dept...
متن کاملThe effect of activated flux type on the weld profile and angular distortion of A-TIG welding of the AISI 2205 duplex stainless steel
In this investigation, the AISI 2205 duplex stainless steel was welded in the form of bead on plate by A-TIG process with different amount of the ZrO2 and TiO2 activated fluxes. The results of the visual inspection showed that the specimen with 50% ZrO2 and 50% TiO2 activated flux, had the lowest face width and the specimen with contains 90% ZrO2 activated flux, had the highest penetration dept...
متن کامل‘Reversed Turkevich’ method for tuning the size of Gold nanoparticles: evaluation the effect of concentration and temperature
In this study the influence of dicarboxy acetone (DCA), as an oxidation product of sodium citrate, was evaluated by ‘reversed Turkevich’ method in this study. Gold nanoparticles (GNPs) were synthesized systematically at various sodium citrate to HAuCl4 molar ratio and temperature. TheseThe GNPs were characterized by UV-vis spectroscopy, DLS and TEM techniques. The results showed that by reversi...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 41 شماره
صفحات -
تاریخ انتشار 2001