BACKGROUND Accurate measurement of blood pressure is of utmost importance in hypertension research. In the context of epidemiologic and clinical studies, oscillometric devices offer important advantages to overcome some of the limitations of the auscultatory method. Even though their accuracy has been evaluated in multiple studies in the clinical setting, there is little evidence of their performance in large epidemiologic studies. OBJECTIVE We evaluated the accuracy of the Omron HEM-705-CP, an automatic device for blood pressure (BP) measurement, as compared to the standard auscultatory method with a mercury sphygmomanometer in a large cohort study. METHODS We made three auscultatory measurements, followed by two measurements with the Omron device in 1,084 subjects. Bias was estimated as the average of the two Omron minus the average of the last two auscultatory measurements, with its corresponding 95% limits of agreement (LA). RESULTS The Omron overestimated systolic blood pressure (SBP) by 1.8 mmHg (LA:-10.1, 13.7) and underestimated diastolic blood pressure (DBP) by 1.6 mmHg (LA:-12.3, 9.2). Bias was significantly larger in men. Bias in SBP increased with age and decreased with BP level, while bias in DBP decreased with age and increased with BP level. The sensitivity and specificity of the Omron to detect hypertension were 88.2% and 98.6%, respectively. Minimum bias in the estimates of the effects of several factors resulted from the use of Omron measurements. CONCLUSION Our results showed that the Omron HEM-705-CP could be used for measuring BP in large epidemiology studies without compromising study validity or precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Evaluation of the Omron 705-CP blood pressure measuring device for use in adolescents and young adults].

OBJECTIVE To assess the Omron 705-CP monitor for measuring blood pressure in adolescents and young adults. METHODS According to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation, we performed validation of the device in 60 adolescents. The Omron monitor was connected in Y to a mercury column. Four consecutive and simultaneous ...

متن کامل

Blood Pressure Measurement Device A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings

Abstract—The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to pre...

متن کامل

Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?

BACKGROUND Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. METHOD This study compared BP measured by two oscillometric de...

متن کامل

Evaluation of the accuracy of the Omron HEM-907 blood pressure device.

A study was undertaken to assess the accuracy of the Omron HEM-907 blood pressure measuring device for use in community studies. A modified version of the British Hypertension Society (BHS) and American Association for the Advancement Medical Instrumentation (AAMI) protocol for measuring the accuracy of a blood pressure measuring device was used. A total of 104 subjects were recruited from two ...

متن کامل

valuation of three devices for self-measurement of blood ressure according to the revised British Hypertension Society rotocol: the Omron HEM=705CP, Philips HP5332, and Nissei

?IJo~ pressure-the Omron HEM-705CP, the Pfirl~ps H P 5 3 3 2 clinical measurement of blood pressure and is the f ~ r s i 5 and the Nisse~ DS175 accord~ng to the rev~sed protocol of the Inexpensive dev~ce to satrsfy the accuracy t I lter la of these ' Pr~hsh Hypertensron Soc~ety (BHS) 7 he results were also protocols aqabed accord~ng to the crlteria for accuracy of the revised sf~ndard of the As...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 96 5  شماره 

صفحات  -

تاریخ انتشار 2011