The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices
نویسندگان
چکیده
Introduction. Manikin studies' data cannot accurately be extrapolated to real-life scenarios and inherent differences in design and materials of newer products may affect their clinical performance. Methods. Hence, we compared the AMBU® Aura-i™ and LMA Supreme™ in this randomized trial involving 100 ASA 1-2 unparalysed anaesthetised patients undergoing minor gynaecological surgery. Investigators had <20 Aura-i insertions. Primary outcome was time to achieve effective ventilation and secondarily insertion parameters, oropharyngeal leak pressures (OLP), fibreoptic positioning, and pharyngeal morbidity. The position of the Ambu Aura-i was evaluated with the Ascope; the fiberoptic view of the glottis was scored on a five-point scale. Results. 43 (86%) AMBU Aura-i and 44 (88%) LMA Supremes were successfully inserted on first attempt (p = 0.59), with similar ease (p = 0.79), and comparable times to first capnogram, mean (SD) 18.2 (6.0) versus 17.3 (6.4) sec, p = 0.9. The Aura-i needed significantly less volume of air to inflate its cuff to 60 cmH2O on the manometer, 17.7 (3.5) versus 23.1 (4.4) mL, p < 0.001. Both devices exhibited similar OLP, Aura-i versus LMA Supreme, mean (SD) 28.8 (7.1) versus 27.3 (5.3) cmH2O, p = 0.24. There was no difference in ease of insertion or adjustment manoeuvres to aid ventilation. 90% of patients had good positioning of Aura-i on fibreoptic check, yielding a view of the vocal cords and epiglottis. In 5 patients (10%), the vocal cords were not seen, but ventilatory function was unaffected. Conclusions. The Aura-i handled well in novices hands, with comparable times to insert and establish ventilation, similar leak pressures, and successful first attempt insertion rates compared to the LMA Supreme.
منابع مشابه
The laryngeal mask airway Supreme--a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients.
The LMA Supreme is a new extraglottic airway device which brings together features of the LMA ProSeal, Fastrach and Unique. We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal and the LMA Supreme in paralysed anesthetised patients. Ninety-three females aged 19-71 years were studied. Bot...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملPediatric supraglottic airway devices in clinical practice: A prospective observational study
BACKGROUND Supraglottic airway devices (SGA) are commonly used in pediatric anesthesia and serve as primary or back-up devices for difficult airway management. Most SGA are marketed without proper clinical evaluation. The purpose of this study was to evaluate the performance of the pediatric LMA Supreme™, Air-Q® and Ambu® Aura-i™. METHODS This prospective observational study was performed at ...
متن کاملRandomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients
BACKGROUND The i-gel™, LMA-Supreme (LMA-S) and Laryngeal Tube Suction-D (LTS-D) are single-use supraglottic airway devices with an inbuilt drainage channel. We compared them with regard to their position in situ as well as to clinical performance data during elective surgery. METHODS Prospective, randomized, comparative study of three groups of 40 elective surgical patients each. Speed of ins...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016