Effectiveness and acceptability of a newly designed hip protector: a pilot study.
نویسندگان
چکیده
Hip fracture has a significant economic and personal cost, involving hospital admission and functional impairment for elderly people. To assess the benefit of using a newly designed hip protector (new material and new design) to prevent fracture in a realistic setting, a randomised intervention-control design was used to trial the effectiveness of pads worn by high falls risk residents (n=71) in nursing home for 9 months. 40 residents were in the intervention group and 31 were in the control group. A profile of falls, including time of day, and orientation was obtained to demonstrate the potential effectiveness of the protectors for injury prevention. Acceptance of the hip protector was also surveyed amongst nursing home staff and residents. One hundred and one falls and six fractures occurred in the control group. In contrast, one hundred and ninety one falls and three fractures occurred in the hip protector (pads) group. The three fractures in the protector wearing group occurred when pads were not in place. This was extrapolated as 1 in every 16.8 falls and 1 in every 63.7 falls resulting in fracture in the two groups, respectively. The relative risk of fracture was 0.264 (95% CI=0.073-0.959) when the fracture incidence rate in the intervention group (three fractures per 191 falls) was compared to the control group (six fractures per 101 falls). This is a statistically significant result and implies that this newly designed hip protector is effective in preventing hip fracture. The majority of falls occurred during the day, which was when protectors were worn in this study, but the data on orientation was incomplete, with direction unknown in 74% of falls. Compliance was an issue, which was interpreted as only 50.3% of falls recorded with protectors in place. Dementia was identified as the explanation for this as the pads were often removed by these residents who comprised the majority of participants. Perception of low risk was the primary barrier to residents accepting the intervention. Comfort of protectors was not a significant concern for staff or residents, and only staff described appearance as an issue. In conclusion, the newly designed hip protector is protective against fractures in a realistic setting. Compliance and acceptance of the protectors will ultimately determine the viability of this prophylaxis.
منابع مشابه
Acceptability and compliance with wearing energy-shunting hip protectors: a 6-month prospective follow-up in a Finnish nursing home.
OBJECTIVES To assess the acceptability and compliance with use of an energy-shunting hip protector in institutionalized elderly people. DESIGN AND SETTING A 6 month prospective follow-up in a Finnish nursing home. PARTICIPANTS 19 ambulatory nursing home residents with a high risk of hip fracture. MAIN OUTCOME MEASURES The proportion of the residents who were willing to use the device, the...
متن کاملHip protector compliance in an acute hospital setting
Objectives. To examine compliance for a newly designed hip protector and reasons for non-compliance among elderly participants with a moderate-to-high risk of falls. Methods. This was a descriptive observational study conducted in acute aged care wards at the Bankstown Hospital, Sydney, Australia. Seventeen in-patients aged between 71 and 95 years in the four aged care wards at the Bankstown Ho...
متن کاملPrevention of hip fracture in elderly people with use of a hip protector.
BACKGROUND Hip fractures are common in frail elderly adults worldwide. We investigated the effect of an anatomically designed external hip protector on the risk of these age-related fractures. METHODS We randomly assigned 1801 ambulatory but frail elderly adults (1409 women and 392 men; mean age, 82 years), in a 1:2 ratio, either to a group that wore a hip protector or to a control group. Fra...
متن کاملThe usability and preliminary effectiveness of a web-based physical activity intervention in patients with knee and/or hip osteoarthritis
BACKGROUND A large proportion of patients with knee and/or hip osteoarthritis (OA) do not meet the recommended levels of physical activity (PA). Therefore, we developed a web-based intervention that provides a tailored PA program for patients with knee and/or hip OA, entitled Join2move. The intervention incorporates core principles of the behaviour graded activity theory (BGA). The aim of this ...
متن کامل[Effectiveness of a multifactorial intervention to reduce physical restraints in nursing home residents with dementia].
At present, observational studies and expert opinion are the best evidence for the use of physical restraints. Large regional and national disparities are described in acute and long-term care. Epidemiological data demonstrate a prevalence of 3-5% body-fixed or near body restraint devices. The hip fracture rate in Germany are approximately 50 per 1000 resident years. Between 40-50% of the resid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of gerontology and geriatrics
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2000