Evaluation of Plume Divergence and Facility Effects on Far-Field Faraday Probe Current Density Profiles

نویسندگان

  • Daniel L. Brown
  • Alec D. Gallimore
چکیده

A Faraday probe with three concentric rings was designed and fabricated to assess the effects of gap width and probe geometry in a systematic study of the Hall thruster plume. The nested Faraday probe consisted of two concentric collector rings and an outer guard ring, which enabled simultaneous current density measurements on the inner and outer collector. Two versions of the outer collector were fabricated to create 0.5 mm or 1.5 mm gaps between the rings. Current density distribution of a Hall thruster ion source were studied at 8, 12, 16, and 20 thruster diameters downstream of the exit plane with four probe configurations at background pressures of 3x10, 1x10, and 3x10 torr. Several correction factors are proposed to account for the effective probe collection area and systematic measurement error associated with measuring an annular device as a point source. These corrections enable the investigation of beam expansion and ion migration from the central core, and result in a highly accurate estimate of divergence in the Hall thruster plume. Application of the correction factors and characterization of facility effects are shown to decrease the calculated beam current by 10-20% compared to conventional analysis and reduce measurement uncertainty to ±3%. DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. 1 Research Scientist, Spacecraft Branch, Propulsion Directorate, AFRL/RZSS, [email protected]. 2 Professor, Department of Aerospace Engineering, Associate Dean, Horace H. Rackham School of Graduate Studies, Director, Plasmadynamics and Electric Propulsion Laboratory, [email protected].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Near-field Ion Current Density Measurements

Faraday probe measurements were taken in the near-field plume of a 6-kW Hall thruster to reduce the negative effects of facility-induced charge-exchange collisions. The results from these measurements were analyzed using a non-standard definition of the current density integration bounds that produced self-consistent beam current and beam divergence values. The measurements indicated a beam div...

متن کامل

The Effects of Nude Faraday Probe Design and Vacuum Facility Backpressure on the Measured Ion Current Density Profile of Hall Thruster Plumes

The effects of dissimilar probe design and facility backpressure on the measured ion current densities of Hall thrusters are investigated. JPL and GRC designed nude Faraday probes are used to simultaneously measure the ion current density of a 5 kW Hall thruster in the Large Vacuum Test Facility (LVTF) at the University of Michigan. The probes are located one meter from the exit plane of the Ha...

متن کامل

Optical Boron Nitride Insulator Erosion Characterization of a 200 W Xenon Hall Thruster

Vacuum ultraviolet emission (137.9 nm) of boron neutrals sputtered from a 200 W xenon Hall thruster boron nitride insulator is evaluated as a diagnostic for real time evaluation of thruster insulator erosion. Three Hall thruster plasma control variables are examined; ion energy (discharge potential), ion flux (propellant flow), and plasma conductivity (magnetic field strength). The boron emissi...

متن کامل

Very-near-field plume study of a 1.35 kW SPT-100

Ion current density and electron number density profiles were measured in the very-nearfield plume of a 1.35 kW stationary plasma thruster (SPT-100) loaned from Space Systems/Loraland Fakel Enterprises. In order to take these measurements without significantly disturbing plasma flow while data were collected, a small Faraday probe and a single Langmuir probe were constructed and used with high-...

متن کامل

Far-Field Plume Measurements of a Nested-Channel Hall-Effect Thruster

Far-field plume measurements were performed on the X2 nested-channel Hall-effect thruster using a nude Faraday probe, retarding potential analyzer, and E×B probe. Data from these probes were used to examine the operating characteristics of the X2 with both channels operating simultaneously (dual-channel mode). For each operating condition in dual-channel mode, far-field measurements were also t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009