Comparison of cation-adjusted Mueller-Hinton broth with Iso-Sensitest broth for the NCCLS broth microdilution method.

نویسندگان

  • L M Koeth
  • A King
  • H Knight
  • J May
  • L A Miller
  • I Phillips
  • J A Poupard
چکیده

Comparison of MIC results obtained in different parts of the world is currently difficult because of variations in methods. In this study, cation-adjusted Mueller-Hinton broth, the NCCLS-recommended medium, was compared with Iso-Sensitest broth, which is widely used in Europe. Microbroth dilution testing, using the NCCLS procedure, was performed on 124 Gram-positive (staphylococci and enterococci) and Gram-negative (Enterobacteriaceae and Pseudomonas aeruginosa) isolates from the CDC reference set, with the only variable being the medium used. Twelve antimicrobial agents were tested: amoxycillin-clavulanic acid, ampicillin, ciprofloxacin, erythromycin, gentamicin, imipenem, levofloxacin, oxacillin, gemifloxacin, trimethoprim- sulphamethoxazole, tetracycline and vancomycin. Vancomycin, erythromycin and oxacillin were only evaluated for the Gram-positive organisms. Trimethoprim-sulphamethoxazole was only evaluated for a subset of Gram-negative organisms because of off-scale results. The 124 isolates were tested in one American and one UK laboratory with two batches of cation-adjusted Mueller-Hinton broth and two of Iso-Sensitest broth. A statistical evaluation of the data used a 24 fully specified factorial analysis to determine if there were significant differences in results owing to Gram reaction, site of testing and type and/or batch of broth. In addition, the cumulative results for each antimicrobial agent in each broth were plotted against the range of MIC dilutions tested. MICs of ciprofloxacin, levofloxacin, gemifloxacin, gentamicin and tetracycline were slightly higher (half a doubling dilution) with Iso-Sensitest broth than with Mueller-Hinton broth. MIC results for the other antimicrobial agents were equivalent. Essential and category agreement rates were comparable for all agents (88.4-100% and 88.2-99.0%, respectively).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phenotypic detection of mecC-MRSA: cefoxitin is more reliable than oxacillin.

OBJECTIVES To investigate the reliability of cefoxitin and oxacillin for the detection of mecC-positive Staphylococcus aureus. METHODS The susceptibility to cefoxitin and oxacillin of 62 mecC-positive S. aureus isolates was investigated using broth microdilution, agar dilution, Etest and disc diffusion on different types of media. The data were interpreted for the utility of cefoxitin and oxa...

متن کامل

Evaluation of the NCCLS M44-P disk diffusion method for determining susceptibilities of 276 clinical isolates of Cryptococcus neoformans to fluconazole.

We evaluated the NCCLS M44-P fluconazole disk diffusion method in comparison with the NCCLS M27-A2 broth microdilution method for determining the susceptibility of 276 isolates of Cryptococcus neoformans. Disk diffusion testing was performed using Mueller-Hinton agar supplemented with 2% glucose and 0.5 microg of methylene blue/ml. Among the 276 isolates, 259 (93.8%) were susceptible, 16 (5.8%)...

متن کامل

Evaluation of the Dade MicroScan MICroSTREP antimicrobial susceptibility testing panel with selected Streptococcus pneumoniae challenge strains and recent clinical isolates.

The MicroScan MICroSTREP panel is a recently marketed frozen broth microdilution panel for susceptibility testing of various streptococci, including Streptococcus pneumoniae. The panel contains 10 antimicrobial agents in cation-adjusted Mueller-Hinton broth supplemented with 3% lysed horse blood, similar in concept to the National Committee for Clinical Laboratory Standards (NCCLS) reference br...

متن کامل

Recommendation for a Standardised Method of Broth Microdilution Susceptibility Testing for Porcine Bordetella bronchiseptica

The objective was to establish and standardise a broth microdilution susceptibility testing method for porcine Bordetella (B.) bronchiseptica. B. bronchiseptica isolates from different geographical regions and farms were genotyped by macrorestriction analysis and subsequent pulsed-field gel electrophoresis. One reference and one type strain plus two field isolates of B. bronchiseptica were chos...

متن کامل

Performance of eight methods, including two new rapid methods, for detection of oxacillin resistance in a challenge set of Staphylococcus aureus organisms.

Using a set of 55 Staphylococcus aureus challenge organisms, we evaluated six routine methods (broth microdilution, disk diffusion, oxacillin agar screen, MicroScan conventional panels, MicroScan rapid panels, and Vitek cards) currently used in many clinical laboratories and two new rapid methods, Velogene and the MRSA-Screen, that require less than a day to determine the susceptibility of S. a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of antimicrobial chemotherapy

دوره 46 3  شماره 

صفحات  -