Impact of different standardized uptake value measures on PET-based quantification of treatment response.

نویسندگان

  • Matt Vanderhoek
  • Scott B Perlman
  • Robert Jeraj
چکیده

UNLABELLED PET-based treatment response studies typically measure the change in the standardized uptake value (SUV) to quantify response. The relative changes of different SUV measures, such as maximum, peak, mean, or total SUVs (SUV(max), SUV(peak), SUV(mean), or SUV(total), respectively), are used across the literature to classify patients into response categories, with quantitative thresholds separating the different categories. We investigated the impact of different SUV measures on the quantification and classification of PET-based treatment response. METHODS Sixteen patients with solid malignancies were treated with a multitargeted receptor tyrosine kinase inhibitor, resulting in a variety of responses. Using the cellular proliferation marker 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), we acquired whole-body PET/CT scans at baseline, during treatment, and after treatment. The highest (18)F-FLT uptake lesions (~2/patient) were segmented on PET images. Tumor PET response was assessed via the relative change in SUV(max), SUV(peak), SUV(mean), and SUV(total), thereby yielding 4 different responses for each tumor at mid- and posttreatment. For each SUV measure, a population average PET response was determined over all tumors. Standard deviation (SD) and range were used to quantify variation of PET response within individual tumors and population averages. RESULTS Different SUV measures resulted in substantial variation of individual tumor PET response assessments (average SD, 20%; average range, 40%). The most extreme variation between 4 PET response measures was 90% in individual tumors. Classification of tumor PET response depended strongly on the SUV measure, because different SUV measures resulted in conflicting categorizations of PET response (ambiguous treatment response assessment) in more than 80% of tumors. Variation of the population average PET response was considerably smaller (average SD, 7%; average range, 16%), and this variation was not statistically significant. Differences in tumor PET response were greatest between SUV(mean) and SUV(total) and smallest between SUV(max) and SUV(peak). Variations of tumor PET response at midtreatment and posttreatment were similar. CONCLUSION Quantification and classification of PET-based treatment response in individual patients were strongly affected by the SUV measure used to assess response. This substantial uncertainty in individual patient PET response was present despite the concurrent robustness of the population average PET response. Given the ambiguity of individual patient PET responses, selection of PET-based treatment response measures and their associated thresholds should be carefully optimized.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function

Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value

Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...

متن کامل

Prognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer

Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 54 8  شماره 

صفحات  -

تاریخ انتشار 2013