Double Bolus Application in TWIST-MR-Angiography of the Cervical Arteries
نویسندگان
چکیده
Purpose. The aim of the present work was to test the feasibility of the time-resolved MR-angiography (TWIST-MRA) of cervical arteries using double bolus injection. Material and Methods. TWIST-MRA with a temporal resolution of 8.4 seconds for each frame and a spatial resolution with a voxel size of 0.61 × 0.58 × 0.8 mm(3) was performed in 24 patients. A biphasic bolus injection protocol was used with the second injection being started 21 seconds after the first contrast dye bolus. Diagnostic image quality was rated according to a 4-point scale. Results. In 12 patients (50%) no clear separation between the cervical venous and arterial vessels was evident after the first bolus injection. Using TWIST-MRA data acquired after the second bolus a sufficient diagnostic image quality (rating ≥3, mean 3.5) could be obtained in 22 of 24 patients (92%). Discussion. The double bolus injection protocol using TWIST-MRA allows for very good separation of the cervical arteries.
منابع مشابه
Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stochastic trajectories (TWIST) with standard high-resolution 3D contrast enhance MR Angiography (HR ceMRA)
¶ Figure 3: Calf station of left lower limb in patient with normal runoff arteries. (A) TWIST demonstrates focal occlusion of the distal anterior tibial artery (arrow) and a high grade stenosis of the distal posterior tibial artery (arrowhead) (B) HR ceMRA demonstrating normally appearing runoff arteries. Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stoc...
متن کاملDynamic contrast-enhanced MR angiography and MR imaging of the carotid artery: high-resolution sequences in different acquisition planes.
BACKGROUND AND PURPOSE First-pass contrast-enhanced MR angiography has become the technique of choice for studying the carotid bifurcation, but this method has some limitations. We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane. METHODS Cervical carotid arteries of 80 consecutive...
متن کاملAutomatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.
For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phase images and mask images to generate an optimal summary arteriogram. A paired ...
متن کاملContrast-enhanced magnetic resonance angiography of the cervical vessels: experience with 422 patients.
BACKGROUND AND PURPOSE Contrast-enhanced magnetic resonance angiography (CEMRA) permits acquisition of high-spatial-resolution, venous-suppressed, 3D MR angiograms of the cervical carotid and vertebral arteries. In this study, an elliptic centric-view ordering with either MR fluoroscopic triggering or test bolus timing was used. The use of CEMRA of the cervical vessels has changed our clinical ...
متن کاملNon-contrast MR Angiography
Figure 1. NC-MRA (inflow inversion recovery) shows normal arterial vasculature of the lower extremities. PA, popliteal artery; AT, anterior tibial arteries; PT, posterior tibial arteries; and PER, peroneal arteries. Techniques for performing non-contrast MR angiography (NC-MRA) have been available since the introduction of MR imaging. These techniques were largely displaced by contrast-enhanced...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012