Piezoelectric Transformer Based Continuous-conduction-mode Voltage Source Charge-pump Power Factor Correction Electronic Ballast

نویسندگان

  • Ray-Lee Lin
  • Hsu-Ming Shih
  • Chen-Yao Liu
  • Kuo-Bin Liu
چکیده

CONDUCTION-MODE VOLTAGE SOURCE CHARGE-PUMP POWER FACTOR CORRECTION ELECTRONIC BALLAST * Ray-Lee Lin, Hsu-Ming Shih, National Cheng Kung University, Tainan, Taiwan Chen-Yao Liu, Kuo-Bin Liu, National Synchrotron Radiation Research Center, Hsinchu, Taiwan Abstract This paper presents the piezoelectric transformer (PT) based continuous-conduction-mode (CCM) voltage source (VS) charge-pump (CP) power factor correction (PFC) electronic ballast. By replacing L-C resonant tank and transformer in the conventional CCM VS CP-PFC electronic ballast with PT, the cost and volume can be reduced. The experimental results show that the electronic ballast using PT achieve high power factor and the switches can be operated under zero-voltageswitching condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of a Radial Mode Piezoelectric Transformer for a Charge Pump Electronic Ballast with High Power Factor and Zero Voltage Switching

Electrical Engineering (ABSTRACT) In a conventional electronic ballast for a fluorescent lamp, inductor-capacitor-transformer tank circuit is used. A Piezoelectric Transformer (PT) can potentially be used to replace such a tank circuit to save space and cost. In the past, ballast design using a PT requires selecting a PT from available samples which are normally not matched to specific applicat...

متن کامل

Power factor correction circuit for low-cost electronic ballast using current-source type

Introduction. With the adoption of standards such as IEC555-2, there is a need to develop electronic ballasts for fluorescent lamps which can perform line current harmonic reduction and high input power factor correction (PFC). Among various filtering techniques, the active power factor corrector with a tioost converter has, been proven to be effective [l 31. The boost-type PFC circuit is one o...

متن کامل

Improved Charge Pump Power Factor Correction Electronic Ballast Based on Class DE Inverter

This paper proposes fluorescent electronic ballast with high power factor and low line input current harmonics. The system performance can be improved by a charged pump circuit. Details of design and circuit operation are described. The proposed electronic ballast is modified from single stage half bridge class D electronic ballast by adding capacitor parallel with each power switch and setting...

متن کامل

A Self-Oscillating Drive for Single-Stage Charge-Pump Power-Factor-Correction Electronic Ballast with Frequency Modulation

=AbstractSingle-stage current-source charge-pump powerfactor-correction (SS CS-CPPFC) electronic ballast employs charge-pump concept to obtain high power factor with low cost. However, the circuit has a poor lamp current crest factor and large lamp output power variation, which deteriorates the lamp life. Feed-forward and/or feedback circuit are usually used to deal with these problems at the p...

متن کامل

Reduction of Harmonics in Electronic Ballast Using Buck Boost Converter

This paper is based on the design and analysis of Total Harmonic Distortion(THD) and power factor for Compact Fluorescent Lamp. In the proposed electronic ballast Buck Boost converter operates in the continuous conduction mode, which provides a constant DC voltage to drive the lamp.By choosing the switching frequency more than the resonant frequency the zero voltage switching is achieved in res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006