Vertical flow immunoassay (VFA) biosensor for a rapid one-step immunoassay.

نویسندگان

  • Young Kyoung Oh
  • Hyou-Arm Joung
  • Sanghyo Kim
  • Min-Gon Kim
چکیده

A highly rapid, one-step immunoassay of high sensitivity C-reactive protein (hsCRP) using a biosensor with a vertical flow immunoassay (VFA) was developed. The VFA biosensor was primarily composed of a sample pad, conjugate pad, FTH film and nitrocellulose (NC) membrane, which were all vertically stacked upon one another. Anti-hsCRP and secondary antibodies were consecutively immobilized on the NC membrane at the position below the holes. Gold nanoparticles (AuNPs) conjugated with another anti-hsCRP antibody were encapsulated in the conjugation pad. Various assay conditions, including the size of the hole and the sample volume, were optimized. Under optimized conditions, hsCRP concentrations from 0.01 to 10 μg mL(-1) were detected within 2 min. In comparison with a lateral flow assay (LFA) system, the VFA sensor showed a gradual increase of signal in a concentration-dependent manner without a hook effect in the tested range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Portable, one-step, and rapid GMR biosensor platform with smartphone interface.

Quantitative immunoassay tests in clinical laboratories require trained technicians, take hours to complete with multiple steps, and the instruments used are generally immobile-patient samples have to be sent in to the labs for analysis. This prevents quantitative immunoassay tests to be performed outside laboratory settings. A portable, quantitative immunoassay device will be valuable in rural...

متن کامل

Microfabricated Qlisa Biosensors with an Embedded Mixing Element

Optically transduced microfluidic immunoassays have proven to be a highly sensitive and rapid method to assess the concentrations of analytes within biological samples. Although microfluidic immunoassays facilitate higher throughput and automation than standard microtiter plates, the immunoreaction within such devices remains diffusion limited unless there is a way to achieve recursive or conti...

متن کامل

Sequential Push-Pull Pumping Mechanism for Washing and Evacuation of an Immunoassay Reaction Chamber on a Microfluidic CD Platform

A centrifugal compact disc (CD) microfluidic platform with reservoirs, micro-channels, and valves can be employed for implementing a complete immunoassay. Detection or biosensor chambers are either coated for immuno-interaction or a biosensor chip is inserted in them. On microfluidic CDs featuring such multi-step chemical/biological processes, the biosensor chamber must be repeatedly filled wit...

متن کامل

Optimization of a commercial biosensor for polychlorinated biphenyls and evaluation of its utility for screening.

We previously described our systematic progress that eventually resulted in a commercially available immunoassay based biosensor (PCB biosensor) for detecting PCBs in oil. However, IC50 of the commercialized PCB biosensor was approximately 2 ppb for PCBs, and did not achieve the theoretical detection limit (TDL) which would represent an IC50 of approximately 0.5 ppb. In this study, we charact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2013