چکیده

The aim of this study was to investigate the radiation exposure of the hands and thyroid glands of orthopaedic surgeon and assistant during procedures involving percutaneous wiring of the hand and wrist. The radiation dose to the hand and thyroid glands was prospectively studied from a total of 30 percutaneous hand and wrist procedures. Four thermolucent densitometers were used to measure the radiation exposure. Cases were divided depending on fracture location (ie. wrist, metacarpal, phalangeal) and surgical experience (i.e. Senior House Officer, Registrar, Consultant). Mean radiation exposure in the hand for the surgeon was 0.80 mSv and 0.87 mSv for the assistant. There was a significant difference in the unshielded thyroid group compared to the shielded thyroid group (p < 0.05). The duration and number of exposure decreases with increasing experience. We also found a trend whereas we operate from proximal to distal (wrist to phalangeal), the total direct hand exposure increases. Radiation exposure in the hands and thyroid glands during percutaneous wiring of hand and wrist procedures were within the recommended limit. However, for the junior orthopaedic trainee, the risk of over radiating oneself is higher as the duration and number of exposure increases. We recommended the use of thyroid shield and adherence to the ALARA principle in any fluoroscopic assisted procedures. Routine monitoring of radiation exposure is essential in preventing radiation related disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure during percutaneous nephrolithotomy; Is there a risk of the patient and the operating team?

Background: The aim of this study was to calculate the radiation amount exposed during percutaneous nephrolithototomy (PCNL) and to make the urologists and other staff sensitive about the radiation risk they were exposed to. Materials and Methods: We measured the radiation exposure during 114 cases of PCNL performed. Thermoluminescent dosimeters (TLD) were placed between the operation table and...

متن کامل

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

متن کامل

Exposure of the surgeon's hands to radiation during hand surgery procedures.

BACKGROUND The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. MATERIAL AND METHODS The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals...

متن کامل

An Estimate of Radiation Dose to the Lens of the Eyes, Parotid Gland, and Thyroid Gland in Dental Panoramic Radiography

Introduction: Dental panoramic radiography (DPR) is one of the most frequent diagnostic X-ray procedures, the application of which is currently on a growing trend. During DPR, several radiosensitive tissues, such as the lens of the eyes, parotid gland, and thyroid gland, contribute to the radiation field, and it is necessary to monitor their received dose. The aim of t...

متن کامل

Radiation exposure of the surgeons in sentinel lymph node biopsy

Background: Sentinel node biopsy (SLNB) is the standard of care for breast cancer treatment and it is getting wide acceptance in Iran. The radiation safety of the procedure has been investigated under controlled conditions, but the standard dose of radiotracer and techniques are not always observed in the community setting. The aim of this study was to assess the magnitude of the absor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2006