Images of absolute retardance L.Deltan, using the rotating polariser method

نویسندگان

  • Geday
  • Kaminsky
  • Lewis
  • Glazer
چکیده

Modulation techniques for measuring changes in optical birefringence, such as the rotating-polariser method (Wood & Glazer, 1980, J. Appl. Crystallogr. 13, 217), allow one to determine |sin delta|, delta = 2piLDeltan/lambda, Deltan = double refraction, L = light path and lambda = wavelength. However, they generally suffer from not providing absolute values of the optical retardance or are limited to relatively low retardance values. In addition, knowledge of the absolute phase is required when establishing the correct values of optical orientation information. In this paper, it is shown how the phase delta, and thus optical retardance, can be extracted from combining measurements of |sin delta| at different wavelengths. The new approach works on each single point of a 2-D picture without the need to correlate with neighbouring points. There is virtually no limit to the retardance, and the computational efforts are small compared with other methods (e.g. Ajovalasit et al. 1998, J. Strain Analysis 33, 75). When used with imaging techniques, such as the rotating polariser method of Glazer, Lewis & Kaminsky 1996 (Proc. R. Soc. London Series A452, 2751) this process has the potential to identify automatically optically anisotropic substances under the microscope. The algorithm derived in this paper is valid not only for birefringence studies, but can be applied to all studies of interfering light waves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration method using a single retarder to simultaneously measure polarization and fully characterize a polarimeter over a broad range of wavelengths.

A method has been developed to improve the accuracy with which the polarization state of light can be characterized by the rotating quarter-wave plate technique. Through detailed analysis, verified by experiment, we determine the positions of the optic axes of the retarder and linear polarizer, and the wave plate retardance, to better than 1° for typical signal-to-noise ratios. Accurate determi...

متن کامل

Optimizing imaging polarimeters constructed with imperfect optics.

Imaging polarimeters are often designed and optimized by assuming that the polarization properties of the optics are nearly ideal. For example, we often assume that the linear polarizers have infinite extinction ratios. It is also usually assumed that the retarding elements have retardances that do not vary either spatially or with the angle of incidence. We consider the case where the polariza...

متن کامل

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

A New Vision-Based and GPS-Signal-Independent Approach in Jamming Detection and UAV Absolute Positioning Assessment

The Unmanned Aerial Vehicles (UAV) positioning in the outdoor environment is usually done by the Global Positioning System (GPS). Due to the low power of the GPS signal at the earth surface, its performance disrupted in the contaminated environments with the jamming attacks. The UAV positioning and its accuracy using GPS will be degraded in the jamming attacks. A positioning error about tens of...

متن کامل

Effects of formalin fixation on tissue optical polarization properties.

Formalin fixation is a preparation method widely used in handling tissue specimens, such as biopsies, specifically in optical studies such as microscopy. In this note, we examine how formalin fixation affects the polarization properties of porcine myocardium and liver as assessed by optical polarimetry. Spatial maps of linear retardance and depolarization were derived from four myocardial and f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of microscopy

دوره 198 (Pt 1)  شماره 

صفحات  -

تاریخ انتشار 2000