Valve or No Valve: A Prospective Randomized Controlled Trial of Casting Options for Pediatric Forearm Fractures.
نویسندگان
چکیده
The purpose of this study was to determine the rate of cast-related complications when using split or intact casts. A total of 60 patients aged 3 to 13 years with closed shaft or distal third radius and ulna fractures requiring reduction were recruited for this study. Patients underwent closed reduction under sedation and were placed into a long-arm fiberglass cast with 1 of 3 modifications: no valve, univalve, or bivalve. Patients were followed to 6 weeks after reduction or surgical treatment if required. The frequency of neurovascular injury, cast saw injury, unplanned office visits, and cast modifications, the need for operative intervention, and pain levels through the follow-up period were recorded. The results showed no incidents of compartment syndrome or neurovascular injury. Additionally, there were no differences between complications associated with cast type (P=.266), frequency of cast modifications (P=.185), or subsequent need for surgical stabilization (P=.361). Therefore, cast splitting following closed reduction of low-energy pediatric forearm fractures does not change clinical outcomes with respect to neurovascular complications, cast modifications, pain levels, or the need for repeat reduction. Consideration should be given to minimizing cast splitting after reduction of low-energy pediatric forearm fractures for practice efficiency and to potentially decrease saw-related injury. [Orthopedics. 2017; 40(5):e849-e854.].
منابع مشابه
A comparison of intervention and conservative treatment for angulated fractures of the distal forearm in children (AFIC): study protocol for a randomized controlled trial
BACKGROUND Angulated fractures of the distal forearm are very frequent lesions in childhood. Currently, there are no standard guidelines on whether these children should be treated conservatively with a cast; with reduction and a cast; or with reduction, pinning and a cast under anesthesia. Minor prospective and retrospective studies have shown that the distal physis of the forearm possesses hi...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملManagement of Pediatric Forearm Torus Fractures: A Systematic Review and Meta-Analysis.
OBJECTIVES Pediatric forearm torus fracture, a frequent reason for emergency department visits, can be immobilized by both rigid cast and nonrigid methods. However, controversy still exists regarding the optimal treatment of the disease. The aim of this study was to compare, in a systematic review, clinical efficacy of rigid cast with nonrigid methods for immobilization of the pediatric forearm...
متن کاملMebeverine for Pediatric Functional Abdominal Pain: A Randomized, Placebo-Controlled Trial
Introduction: Few studies are conducted on the efficacy of antispasmodics in the treatment of functional gastrointestinal disorders in children. We evaluated the effectiveness of a smooth-muscle relaxant (mebeverine) in the treatment of childhood functional abdominal pain (FAP). Materials and Methods: Children (n=115, aged 6-18 years) with FAP were randomized to receive mebeverine 135 mg...
متن کاملSHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY
BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 40 5 شماره
صفحات -
تاریخ انتشار 2017