Spectral measurement of the caesium D(2) line with a tunable heterodyne interferometer.

نویسندگان

  • Luca Spani Molella
  • Rolf-Hermann Rinkleff
  • Karsten Danzmann
چکیده

The optical properties of a caesium atomic beam driven on a resonant hyperfine transition in the D(2) line were studied as a function of the probe laser frequency. Using a third off-resonant laser system, a heterodyne interferometer allowed simultaneous absorption and phase shift measurements of either the probe or the coupling laser. The signal features of the probe and coupling laser transmitted intensities showed strong differences in the vicinity of the hyperfine transitions excited by the probe laser. Regular absorption signals and electromagnetically induced transparency were found in either transmitted intensities. Furthermore, light induced birefringence of the probe laser was measured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Error Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer

A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Noise Suppression on the Tunable Laser for Precise Cavity Length Displacement Measurement

The absolute distance between the mirrors of a Fabry-Perot cavity with a spacer from an ultra low expansion material was measured by an ultra wide tunable laser diode. The DFB laser diode working at 1542 nm with 1.5 MHz linewidth and 2 nm tuning range has been suppressed with an unbalanced heterodyne fiber interferometer. The frequency noise of laser has been suppressed by 40 dB across the Four...

متن کامل

Solar CIV vacuum-ultraviolet Fabry-Perot interferometers

Aims. A tunable, high spectral resolution, high effective finesse, vacuum ultraviolet (VUV) Fabry-Perot interferometer (FPI) is designed for obtaining narrow-passband images, magnetograms, and Dopplergrams of the transition region emission line of CIV (155 nm). Methods. The integral part of the CIV narrow passband filter package (with a 2–10 pm FWHM) consists of a multiple etalon system compose...

متن کامل

Abstract—Heterodyne receivers at millimeter and sub- millimeter wavelength are widely used for radiometric spectral line observations for atmospheric remote sensing or radio

Heterodyne receivers at millimeter and submillimeter wavelength are widely used for radiometric spectral line observations for atmospheric remote sensing or radio astronomy. The quantitative analysis of such observations requires an accurate knowledge of the mixers’s sideband ratio. In addition, its potential sensitivity to spurious harmonics needs to be well understood. In this paper, we discu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

دوره 63 5  شماره 

صفحات  -

تاریخ انتشار 2006