Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.

نویسندگان

  • Darinka Todorova Petrova
  • Gabriela Ariadna Cocisiu
  • Christoph Eberle
  • Karl-Heinz Rhode
  • Gunnar Brandhorst
  • Philip D Walson
  • Michael Oellerich
چکیده

OBJECTIVES The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). METHODS The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb concentrations were estimated from the HI using the Roche Modular automated platform in self-made and commercially available quality controls, as well as samples from a proficiency testing scheme (INSTAND). The fHb using Roche automated HI results were then compared to results obtained using the traditional spectrophotometric assays for one hundred plasma samples with varying degrees of hemolysis, lipemia and/or bilirubinemia. RESULTS The novel method using automated HI quantification on the Roche Modular clinical chemistry platform correlated well with results using the classical methods in the 100 patient samples (Harboe: r = 0.9284; Fairbanks et al.: r = 0.9689) and recovery was good for self-made controls. However, commercially available quality controls showed poor recovery due to an unidentified matrix problem. CONCLUSIONS The novel method produced reliable determination of fHb in samples without interferences. However, poor recovery using commercially available fHb quality control samples currently greatly limits its usefulness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin.

OBJECTIVE In this study, we determined the assay performance criteria necessary to produce acceptable results for >or=98% of neonate bilirubin samples collected by capillary heel-stick. STUDY DESIGN AND METHODS We determined serum free hemoglobin levels in 151 heel-stick serum samples to determine the hemolysis level. We then tested the effect of hemolysis on total bilirubin levels determined...

متن کامل

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory

OBJECTIVES The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND METHODS Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was ...

متن کامل

In-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump

Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...

متن کامل

Dengue with Normal Platelet Count and no Hemoconcentration: Automated Hematogram in Cases with Underlying Thalassemia

Dear Editor, Dengue is an important arbovirus infection. This infection can result in an acute febrile illness. The important hematological abnormalities included hemoconcentration and thrombocytopenia (1). Due to the decreased platelet count, the patient might develop petechiae and hemorrhagic complication. In endemic area, the presumptive diagnosis of dengue is usually derived by the cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biochemistry

دوره 46 13-14  شماره 

صفحات  -

تاریخ انتشار 2013