Flattening filter‐free linac improves treatment delivery efficiency in stereotactic body radiation therapy

نویسندگان

  • Brendan M. Prendergast
  • John B. Fiveash
  • Richard A. Popple
  • Grant M. Clark
  • Evan M. Thomas
  • Douglas J. Minnich
  • Rojymon Jacob
  • Sharon A. Spencer
  • James A. Bonner
  • Michael C. Dobelbower
چکیده

Stereotactic body radiation therapy (SBRT) employs precision target tracking and image-guidance techniques to deliver ablative doses of radiation to localized malignancies; however, treatment with conventional photon beams requires lengthy treatment and immobilization times. The use of flattening filter-free (FFF) beams operating at higher dose rates can shorten beam-on time, and we hypothesize that it will shorten overall treatment delivery time. A total of 111 lung and liver SBRT cases treated at our institution from July 2008 to July 2011 were reviewed and 99 cases with complete data were identified. Treatment delivery times for cases treated with a FFF linac versus a conventional dose rate linac were compared. The frequency and type of intrafraction image guidance was also collected and compared between groups. Three hundred and ninety-one individual SBRT fractions from 99 treatment plans were examined; 36 plans were treated with a FFF linac. In the FFF cohort, the mean (± standard deviation) treatment time (time elapsed from beam-on until treatment end) and patient's immobilization time (time from first alignment image until treatment end) was 11.44 (± 6.3) and 21.08 (± 6.8) minutes compared to 32.94 (± 14.8) and 47.05 (± 17.6) minutes for the conventional cohort (p < 0.01 for all values). Intrafraction-computed tomography (CT) was used more often in the conventional cohort (84% vs. 25%; p < 0.05), but use of orthogonal X-ray imaging remained the same (16% vs. 19%). For lung and liver SBRT, a FFF linac reduces treatment and immobilization time by more than 50% compared to a conventional linac. In addition, treatment with a FFF linac is associated with less physician-ordered image guidance, which contributes to further improvement in treatment delivery efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Stereotactic Body Radiotherapy for Small Lung Tumors in the University of Tokyo Hospital

Our work on stereotactic body radiation therapy (SBRT) for primary and metastatic lung tumors will be described. The eligibility criteria for SBRT, our previous SBRT method, the definition of target volume, heterogeneity correction, the position adjustment using four-dimensional cone-beam computed tomography (4D CBCT) immediately before SBRT, volumetric modulated arc therapy (VMAT) method for S...

متن کامل

Impact of flattening-filter-free techniques on delivery time for lung stereotactic volumetric modulated arc therapy and image quality of concurrent kilovoltage cone-beam computed tomography: a preliminary phantom study

To the Editor, Volumetric modulated arc therapy (VMAT) serves as a means for stereotactic hypofractionated treatment of lung tumors [1]. The present authors proposed an efficient VMAT sequence by restricting leaf speeds of a multi-leaf collimator per gantry rotation angle to below 1 mm/degree, thereby reducing the dose delivery time down to 210 s for a D95 prescription dose of 50 Gy in four fra...

متن کامل

A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams

To investigate potential dosimetric benefits and treatment efficiency of dynamic conformal arc therapy (DCA), intensity modulated radiation therapy (IMRT), and double partial arcs Rapidarc (RA) techniques in the treatment of early-stage peripheral lung cancer using stereotactic body radiotherapy (SBRT) with flattening filter free (FFF) beams. Twenty early-stage peripheral lung cancer patients w...

متن کامل

Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Peripheral Lung Cancer with Flattening Filter Free Beams

PURPOSE To investigate the performance of using partial arc (PA) and full arc with avoidance sectors (FAAS) in stereotactic body radiotherapy (SBRT) of peripheral lung cancer with flattening filter free (FFF) beams. METHODS Eighteen patients with primary (T1 or T2) non-small-cell lung cancer (NSCLC) or lung metastatic were selected for this study. Nine patients with a gross tumor volume (GTV)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -