Facilitating tracheal intubation by additional conduit on GlideScope videolaryngoscope blade.

نویسندگان

  • Jian H Liu
  • Fu S Xue
  • Yi Cheng
  • Rui P Li
  • Abdullah M Kaki
چکیده

We read with interest the recent article of Almarakbi et al1 regarding the use of an additional conduit to facilitate tracheal intubation with GlideScope videolaryngoscope (GSVL) in patients with a normal airway. They showed that compared with the standard intubation procedure with the GSVL, this modified technique made the passage of the tracheal tube easier and intubation time shorter, without increasing adverse events, or intubation failure. This method appears interesting, but there are several aspects of this modified technique that need to be clarified before adoption into routine practice. We believe that such information would be helpful for others who would like to try this modified technique. First, the authors in their study1 described that this modified blade was developed by attaching a tracheal tube to the right side of the GSVL blade with adhesive tapes. However, in Figure 1, we did not see any tape fixation location. It was unclear, whether multiple fixations were needed to obtain a firm attachment. We are concerned that the adhesive tapes placed on the distal part of the GSVL blade may obstruct, or affect the visualization of the camera located midway along the bottom of the blade.2 Second, the lateral wall of the attached tracheal tube was split throughout its length. It would be interesting to know how to keep the lumen of the attached tracheal tube open for easy passage of the tracheal tube. Does it need to remove a part of lateral wall of the attached tube? Third, the length of the attached tube was cut to match the length of the GSVL blade, and the distal end of the attached tube was positioned at the GSVL blade tip. The manufacturer’s description specifies that the GSVL is introduced into the patient’s mouth along the midline, the blade tip is placed into the epiglottic vallecula, and gently lifted to expose the glottis.3 In this case, the glottis is under the epiglottic vallecula, and there are soft tissues and epiglottis between the GSVL blade tip and the anterior commissure. Therefore, when the tracheal tube is advanced along the attached conduit on the right side of the GSVL blade, the tube tip would be directed into the epiglottic vallecula on upper right of the glottis. Even the epiglottis may also obstruct the correct insertion of the tracheal tube. It would be interesting to know, whether the standard intubation procedure with the GSVL is needed to change when this modified blade is used. Fourth, because the distal end of the attached tube was positioned at the GSVL blade tip, the distal part of the attached tube before the camera of the GSVL may limit field of view on the right side. Also, it can obstruct observation of tracheal tube insertion. Currently, there are several different channelled rigid indirect laryngoscopes available, such as Airtraq optical laryngoscope (Prodol, Vizcaya, Spain), Pentax-Airway Scope (Pentax-AWS, Ambu Glen Burnie MD, USA), and AP Venner scope (Intavent Direct, Maidenhead, UK).3-5 Similarly, these devices incorporate a tube guiding channel to the right of the viewing axis. However, the distal ends of their tube guiding channels are designed at the sites close to the viewing lens, or the cameras on the middle or distal part of the blade for visualization of the larynx, and the tube tip movement during laryngoscopy and intubation. Fifth, the GSVL has a curved blade with a 60o angle.2 As the attached tracheal tube is curved to follow the contour of the GSVL blade and split to become open, there is a potential risk of tracheal tube slipping out of this added conduit during intubation, especially when a large tracheal tube passes the maximal curve site of the attached tracheal tube on the midway. The authors should provide some suggestions to prevent this issue, and allow them to achieve successful intubation. Finally, other than difficulty with the introduction of tracheal tube through the glottis, another issue of intubation with the GSVL is difficulty with advancement of the tracheal tube into the trachea, after its tip has passed the glottis and the stylet has been removed.2-4 This situation often results from the tube tip being snagged in the anterior tracheal wall, because an inherent anterior curvature of tracheal tube and a 60° curve configuration in the styletted tracheal tube will always result in a tendency that the tracheal tube is advanced anteriorly.6 This modified technique reported by the authors seems inadequate to solve this issue because the tracheal tube within the attached conduit tends to move anteriorly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic response to laryngoscopy in ischemic heart disease: Macintosh blade versus GlideScope videolaryngoscope

Objective To determine the hemodynamic response to laryngoscopy/tracheal intubation using GlideScope® videolaryngoscope in patients with ischemic heart diseases. Methods In a randomized clinical trial, 80 adult patient, candidate for coronary artery bypass graft surgery were allocated in two groups for laryngoscopy (MC=Macintosh blade or GS=GlideScope). The hemodynamic response, laryngoscopy ti...

متن کامل

Adding a conduit to GlideScope blade facilitates tracheal intubation. Prospective randomized study.

OBJECTIVE To determine the effect of modifying the GlideScope (GVL) blade on the intubation time. METHODS This prospective study was conducted at the Department of Anesthesia, King Abdulaziz University Hospital, Jeddah, Saudi Arabia between June 2011 and October 2011. Sixty patients requiring endotracheal tube (ETT) intubation for elective surgery in whom airway was anticipated normal were ra...

متن کامل

A comparison of videolaryngoscopes for tracheal intubation in predicted difficult airway: a feasibility study

BACKGROUND Videolaryngoscopy has become increasingly attractive for the routine management of the difficult airway. Glidescope® is well studied in the literature while imago V-Blade® is a recent videolaryngoscope. This is a feasibility study with 1:1 case-control sequential allocation comparing Imago V-Blade ® and Glidescope® in predicted difficult airway settings. METHODS Two senior anesthes...

متن کامل

A comparison of the Glidescope® to the McGrath® videolaryngoscope in patients

BACKGROUND The Glidescope® videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. METHODS Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computer-generat...

متن کامل

Comparison of the glidescope, CMAC, storz DCI with the Macintosh laryngoscope during simulated difficult laryngoscopy: a manikin study

UNLABELLED BACKGROUND Videolaryngoscopy presents a new approach for the management of the difficult and rescue airway. There is little available evidence to compare the performance features of these devices in true difficult laryngoscopy. METHODS A prospective randomized crossover study was performed comparing the performance features of the Macintosh Laryngoscope, Glidescope, Storz CMAC a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Saudi medical journal

دوره 33 12  شماره 

صفحات  -

تاریخ انتشار 2012