Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM.
نویسنده
چکیده
Reliability, the consistency of a test or measurement, is frequently quantified in the movement sciences literature. A common metric is the intraclass correlation coefficient (ICC). In addition, the SEM, which can be calculated from the ICC, is also frequently reported in reliability studies. However, there are several versions of the ICC, and confusion exists in the movement sciences regarding which ICC to use. Further, the utility of the SEM is not fully appreciated. In this review, the basics of classic reliability theory are addressed in the context of choosing and interpreting an ICC. The primary distinction between ICC equations is argued to be one concerning the inclusion (equations 2,1 and 2,k) or exclusion (equations 3,1 and 3,k) of systematic error in the denominator of the ICC equation. Inferential tests of mean differences, which are performed in the process of deriving the necessary variance components for the calculation of ICC values, are useful to determine if systematic error is present. If so, the measurement schedule should be modified (removing trials where learning and/or fatigue effects are present) to remove systematic error, and ICC equations that only consider random error may be safely used. The use of ICC values is discussed in the context of estimating the effects of measurement error on sample size, statistical power, and correlation attenuation. Finally, calculation and application of the SEM are discussed. It is shown how the SEM and its variants can be used to construct confidence intervals for individual scores and to determine the minimal difference needed to be exhibited for one to be confident that a true change in performance of an individual has occurred.
منابع مشابه
Reliability of isokinetic ankle dorsiflexor strength measurements in healthy young men and women.
The purposes of this study were: (i) to determine the test-retest reliability of isokinetic ankle dorsiflexor strength measurements in young healthy adults using the Biodex dynamometer, and (ii) to examine several statistical measures for the interpretation of reliability. Thirty men and women (mean age 23 +/- 3 years) performed three maximal concentric contractions at 30 degrees/s, 60 degrees/...
متن کاملTest-retest reliability and minimal detectable change scores of twelve functional fitness tests in adults with Down syndrome.
AIM The purpose of the study was to explore the test-retest reliability and minimal detectable change of selected functional fitness test items in adults with Down syndrome. METHODS Forty-three adults with Down syndrome (24 men and 19 women) aged 18-50 years completed a battery of tests twice in a two-week period. The battery of tests consisted of two balance items, two flexibility items, fiv...
متن کاملTest-Retest and Inter-Rater Reliability Study of the Schedule for Oral-Motor Assessment in Persian Children
Objectives: Reliable and valid clinical tools to screen, diagnose, and describe eating functions and dysphagia in children are highly warranted. Today most specialists are aware of the role of assessment scales in the treatment of affected individuals. However, the problem is that the clinical tools used might be nonstandard, and worldwide, there is no integrated assessment performed to assess ...
متن کاملValidity and Reliability of Persian Version of Craig Hospital Inventory of Environmental Factors (CHIEF) in Children with Cerebral Palsy
Objectives: The aim of this study was to translate the Craig Hospital Inventory of Environmental Factors (CHIEF) into Persian language and to evaluate the validity and reliability of Persian version of CHIEF to use for children with cerebral palsy. Methods: The CHIEF was translated from English into Persian based on the International Quality of Life Assessment (IQOLA) approach. The Persian v...
متن کاملQuantitative Mechanical Properties of the Relaxed Biceps and Triceps Brachii Muscles in Patients with Subacute Stroke: A Reliability Study of the Myoton-3 Myometer
Objective. Test-retest reliability of the myotonometer was investigated in patients with subacute stroke. Methods. Twelve patients with substroke (3 to 9 months poststroke) were examined in standardized testing position twice, 60 minutes apart, with the Myoton-3 myometer to measure tone, elasticity, and stiffness of relaxed bilateral biceps and triceps brachii muscles. Intrarater reliability of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of strength and conditioning research
دوره 19 1 شماره
صفحات -
تاریخ انتشار 2005