Comparison of fluorescence polarization immunoassay, enzyme immunoassay, and thin-layer chromatography for urine cannabinoid screening. Effects of analyte adsorption and vigorous mixing of specimen on detectability.

نویسندگان

  • P Dextraze
  • W C Griffiths
  • P Camara
  • L Audette
  • M Rosner
چکیده

Four commercial assays for the screening of cannabinoids in urine were compared. Urine specimens from 93 selected subjects were run by fluorescence polarization immunoassay on the Abbott TDx; by enzyme multiplied immunoassay with two Syva EMIT assays; and by thin-layer chromatography with the TOXI-LAB system (Marion Laboratories). The TDx cannabinoid threshold can be set anywhere from 25 to 150 micrograms per L. Twenty-five micrograms per L was chosen for this study. The thresholds for EMIT are fixed at 20 micrograms per L for one assay and 100 micrograms per L for the other. The detection limit for TOXI-LAB, according to the manufacturer, can be anywhere from 5 to 50 micrograms/L, depending on the specimen. Urines, positive by at least one method, were further analyzed by gas chromatography with mass spectrometry (GC/MS), The detection limit for the GC/MS method was 10 micrograms per L. The results showed a few false negatives and unconfirmable positives; in general, correlation was considered acceptable. Dose-response curves comparing TDx and EMIT gave paralell results, with comparable cross-reactivity for the major metabolite, 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid (delta-9-THC-COOH). A dose-response study of TOXI-LAB using delta-9-THC-COOH also gave acceptable results. Adsorption to glass was investigated using spiked urine; a 27 percent reduction in concentration was caused by this phenomenon. Foaming of spiked urine caused by vigorous mixing resulted in a reversible 89 percent apparent reduction in concentration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical issues associated with urine testing of substances of abuse.

Several factors may affect the validity and outcome of urine testing for abused drugs such as amphetamines, barbiturates, benzodiazepines, cannabinoids, cocaine, ethanol, opiates, and phencyclidine. Urine is used for large-scale testing because acquisition of the sample is noninvasive and because most abused drugs can be detected in urine for a reasonable duration after ingestion. Urine testing...

متن کامل

Single-reagent polarization fluoroimmunoassay for barbiturates in urine.

We describe a rapid polarization fluoroimmunoassay for screening for the presence of barbiturates in urine. The single reagent is prepared by pre-mixing antiserum with a fluorescein-labeled barbiturate derivative as tracer. Use of a mixture of two sheep antisera, raised against different barbiturate immunogens, results in an assay with a broad cross-reactivity spectrum for most common barbitura...

متن کامل

Comparison of Common Commercial Immunoassay Kits for Effective Application in Workplace Drug Urinalysis

Workplace drug urinalysis protocols include an initial immunoassay followed by a confirmatory gas chromatography/mass spectrometry (GC/MS) test of immunoassaypositive samples. (Drug categories that are commonly tested include: amphetamines, barbiturates, benzodiazepines, cannabis, cocaine, lysergic acid diethylamide, methadone, methaqualone, opiates, phencyclidine, and propoxyphene. Not all dru...

متن کامل

Automated liquid-chromatographic analyzer used for toxicology screening in a general hospital: 12 months' experience.

We evaluated the clinical utility of an automated HPLC system (Remedi, Bio-Rad) for identification of drugs and metabolites in biological fluids. Serum or urine or both from 354 consecutive cases of poisoning were analyzed by the system and by a set of fluorescence polarization immunoassay (FPIA, Abbott) and thin-layer chromatographic (TLC) procedures. Antidepressants and most phenothiazines we...

متن کامل

Prevalence of opioid use based on urine sample among men referred to one of the clinical laboratories in Kerman,Iran

Introduction: Comparing to other health problems, substance use epidemiology is a new area of research in Iran. The aim of this study was to determine the prevalence of opioid use among referees to a clinical laboratory by drug testing. Methods: In this cross-sectional study, the urine sample of 1120 consecutive individuals referred to a major clinical laboratory in Kerman city were tested for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1989