MRI-based correction for partial-volume effect improves detectability of intractable epileptogenic foci on 123I-iomazenil brain SPECT images.
نویسندگان
چکیده
UNLABELLED (123)I-Iomazenil brain SPECT has been used for the detection of epileptogenic foci, especially when surgical intervention is considered. Although epileptogenic foci exhibit a decrease in (123)I-iomazenil accumulation, normal cerebral cortices often exhibit similar findings because of thin cortical ribbons, gray matter atrophy, or pathologic brain structures. In the present study, we created (123)I-iomazenil SPECT images corrected for gray matter volume using MRI and tested whether the detectability of the epileptogenic foci improved. METHODS Seven patients (1 male patient and 6 female patients; mean age +/- SD, 34 +/- 17 y) with intractable epilepsy were surgically treated by resecting the cerebral cortex after surface electroencephalography. Histopathologic examination of the resected specimens and a good outcome after surgery indicated that the resected lesions were epileptogenic foci. These patients underwent (123)I-iomazenil SPECT and 3-dimensional T1-weighted MRI examinations before their operations. Each SPECT image was coregistered to the corresponding MR image, and its partial-volume effect (PVE) was corrected on a voxel-by-voxel basis with a smoothed gray matter distribution image. Four nuclear medicine physicians visually evaluated the (123)I-iomazenil SPECT images with and without the PVE correction. The SPECT count ratio of the suspected focus to the contralateral cerebral cortex was evaluated as an asymmetry index (%) based on the volume of interest. RESULTS The sensitivity, specificity, and accuracy of focus detection by visual assessment were higher after PVE correction (88%, 99%, and 98%, respectively) than before correction (50%, 92%, and 87%, respectively). The mean asymmetry index for the surgically resected lesions was significantly higher on the PVE-corrected SPECT images (22%) than on the PVE-uncorrected ones (16%) (P = 0.006). CONCLUSION MRI-based PVE correction for (123)I-iomazenil brain SPECT improves the sensitivity and specificity of the detection of cortical epileptogenic foci in patients with intractable epilepsy.
منابع مشابه
MR imaging-based correction for partial volume effect improves detectability of intractable epileptogenic foci on iodine 123 iomazenil brain SPECT images: an extended study with a larger sample size.
BACKGROUND AND PURPOSE It has been suggested, on the basis of a previous pilot study conducted in a small number of patients, that MR imaging-based PVE correction in I-123 iomazenil brain SPECT improves the detectability of cortical epileptogenic foci. In the present study, we performed an investigation by using a larger sample size to establish the effectiveness of the PVE correction and to co...
متن کاملCorrect localization of epileptogenic focus with I-123 iomazenil cerebral benzodiazepine receptor imaging: a case report of temporal lobe epilepsy with discordant ictal cerebral blood flow SPECT.
A 26-year-old female with intractable epileptic seizures was studied with I-123 iomazenil cerebral benzodiazepine receptor, I-123 IMP inter-ictal and Tc-99m ECD ictal cerebral blood flow SPECT. The ictal cerebral blood flow SPECT indicated the location of the seizures to be in the left temporal lobe, where increased regional cerebral blood flow was noted in marked contrast to the inter-ictal SP...
متن کاملPresurgical Evaluation of Epileptogenic Focus in Temporal Lobe Epilepsy by 11 C - Flumazenil PET and 123 I - Iomazenil SPECT : A Case Report
Meticulous neuroradiological evaluations, including 123I-iomazenil (IMZ) single photon emission computed tomography (SPECT) and 11C-flumazenil (FMZ) positron emission tomography (PET), preoperatively disclosed epileptogenic foci in a 16-year-old boy with temporal lobe epilepsy. Interictal scalp electroencephalography showed spikes in the left temporal region. Left hippocampal sclerosis was seen...
متن کاملDistribution of cortical benzodiazepine receptor binding in right-handed healthy humans: a voxel-based statistical analysis of iodine 123 iomazenil SPECT with partial volume correction.
BACKGROUND AND PURPOSE CBR imaging is highly susceptible to a PVE produced by morphologic changes in the brain related to aging and brain laterality. We assessed the influence of PVE produced by regional age-related changes in gray matter volume on I-123 iomazenil SPECT and elucidated the age-related changes in human CBR binding by using PVE-corrected SPECT images. MATERIALS AND METHODS Ninet...
متن کاملScatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging.
UNLABELLED The aim of this study was to elucidate the clinical usefulness of scatter correction with an artificial neural network (ANN) in 99mTc and 123I dual-isotope SPECT. METHODS Two algorithms for ANN scatter correction were tested: ANN-10 and ANN-3 employing 10 and 3 energy windows for data acquisition, respectively. Three patients underwent myocardial or brain SPECT with one of the foll...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2008