Fast CT-CT fluoroscopy registration with respiratory motion compensation for image-guided lung intervention

نویسندگان

  • Po Su
  • Zhong Xue
  • Kongkuo Lu
  • Jianhua Yang
  • Stephen T. Wong
چکیده

CT-fluoroscopy (CTF) is an efficient imaging method for guiding percutaneous lung interventions such as biopsy. During CTF-guided biopsy procedure, four to ten axial sectional images are captured in a very short time period to provide nearly real-time feedback to physicians, so that they can adjust the needle as it is advanced towards the target lesion. Although popularly used in clinics, this traditional CTF-guided intervention procedure may require frequent scans and cause unnecessary radiation exposure to clinicians and patients. In addition, CTF only generates limited slices of images and provides limited anatomical information. It also has limited response to respiratory movements and has narrow local anatomical dynamics. To better utilize CTF guidance, we propose a fast CT-CTF registration algorithm with respiratory motion estimation for image-guided lung intervention using electromagnetic (EM) guidance. With the pre-procedural exhale and inhale CT scans, it would be possible to estimate a series of CT images of the same patient at different respiratory phases. Then, once a CTF image is captured during the intervention, our algorithm can pick the best respiratory phase-matched 3D CT image and performs a fast deformable registration to warp the 3D CT toward the CTF. The new 3D CT image can be used to guide the intervention by superimposing the EM-guided needle location on it. Compared to the traditional repetitive CTF guidance, the registered CT integrates both 3D volumetric patient data and nearly real-time local anatomy for more effective and efficient guidance. In this new system, CTF is used as a nearly real-time sensor to overcome the discrepancies between static pre-procedural CT and the patient’s anatomy, so as to provide global guidance that may be supplemented with electromagnetic (EM) tracking and to reduce the number of CTF scans needed. In the experiments, the comparative results showed that our fast CT-CTF algorithm can achieve better registration accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

Online 4-D CT Estimation for Patient-Specific Respiratory Motion Based on Real-Time Breathing Signals

In image-guided lung intervention, the electromagnetic (EM) tracked needle can be visualized in a pre-procedural CT by registering the EM tracking and the CT coordinate systems. However, there exist discrepancies between the static pre-procedural CT and the patient due to respiratory motion. This paper proposes an online 4-D CT estimation approach to patient-specific respiratory motion compensa...

متن کامل

Lung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided

Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...

متن کامل

Validation of 3D motion tracking of pulmonary lesions using CT fluoroscopy images for robotically assisted lung biopsy

As recently proposed in our previous work, the two-dimensional CT fluoroscopy image series can be used to track the three-dimensional motion of a pulmonary lesion. The assumption is that the lung tissue is locally rigid, so that the realtime CT fluoroscopy image can be combined with a preoperative CT volume to infer the position of the lesion when the lesion is not in the CT fluoroscopy imaging...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012