Influence of abutment design on retention of metal copings cemented to implants

نویسندگان

  • Albano Porto da Cunha Jr
  • Glauco Pereira Moysés
  • Ana Christina Claro Neves
  • Rafael Pino Vitti
  • Flávia Cardoso da Rosa Goulart
  • Laís Regiane da Siva-Concílio
چکیده

Objective The study evaluated the influence of abutment design on the retention of implant-cemented metal copings. Material and methods Two abutments of the same system with the same indications, height and the total occlusal convergence, but of different designs were evaluated. Ten RN synOcta abutments (Straumann, Waltham, MA) and ten RN titanium solid abutments (Straumann, Waltham, MA) were tightened to 35 Ncm on 20 implant analogs previously placed in resin blocks. Twenty plastic burnout copings were waxed, included, cast and machined by a single operator. Coping was inspected for surface irregularities using a stereomicroscope at 10x magnification, and then, they were cemented (Temp Bond NE, Kerr, Romulus, MI) with 5 kg load for 10 min. The samples were stored for 24 h in room temperature and 100% humidity and then subjected to pull-out test at a crosshead speed of 0.5 mm/min. The load required to dislodge each coping was recorded (kgf) and and mean values for each group statistically calculated. Means and standard deviations of loads at failure were analyzed using Student's t-test. Results The mean load required to dislodge the copings showed by synOcta abutments (11.19 kgf) was statiscally higher than s solid abutments (10.18 kgf). Conclusions: It was concluded that the abutment design influenced significantly the retention of metal copings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Effects of abutment and screw access channel modification on dislodgement of cement-retained implant-supported restorations.

This study investigated the influence of implant abutment and screw access channel modification on the retention of copings. Titanium abutment access openings were either left open or modified by placing two vent holes 3 mm from the occlusal edge and 180 degrees apart. Access openings sealed with a resin material were used as controls. Metal copings were cemented and subjected to tensile testin...

متن کامل

Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns

Background and aims. Because of compromised angulations of implants, the abutments are sometimes prepared. The purpose of this study was to investigate the effect of removing one wall of the implant abutment on the retention of cement-retained crowns. Materials and methods. Four prefabricated abutments were attached to analogues and embedded in acrylic resin blocks. The first abutment was left ...

متن کامل

Effect of using nano and micro airborne abrasive particles on bond strength of implant abutment to prosthesis.

Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne abrasive particles (ABAP) in roughening surface of implant abutments and furt...

متن کامل

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

PURPOSE The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2016