Frozen section in thyroid surgery: is it a necessity?

نویسندگان

  • Bahadir Cetin
  • Sabahattin Aslan
  • Celal Hatiboglu
  • Bahattin Babacan
  • Akin Onder
  • Alper Celik
  • Abdullah Cetin
چکیده

INTRODUCTION Many surgeons use intraoperative frozen-section (FS) biopsy of thyroid nodules to predict malignant disease, but the findings are often not in agreement with those of fine-needle aspiration (FNA) biopsy. Our objective in this study was to assess the value of intraoperative FS biopsy in patients with nodular disease of the thyroid gland. METHODS In this study, 203 patients underwent thyroid surgery at the Ankara Oncology Hospital. Nodules were assessed by FNA biopsy preoperatively, by FS intraoperatively and by histologic examination of the excised specimen. Sensitivity, specificity and accuracy were determined for FS and FNA with respect to the histologic findings. RESULTS The sensitivity, specificity and accuracy rates for FNA, excluding occult cancers, were 74.1%, 100% and 95.2%, respectively, and for FS were 87.1%, 100% and 97.8%, respectively. FS influenced operative decisions in 0.6% of nodules found to be benign by FNA and in 20% of nodules found to be suspicious by FNA. FS contributed nothing for FNA-malignant disease since all the results in this group were true positive. CONCLUSIONS Intraoperative FS was most helpful when the FNA findings were suspicious for malignant disease. FS does not seem to be necessary when FNA indicates malignant or benign disease. Both FNA and FS failed to detect occult thyroid carcinomas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study

Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...

متن کامل

Evaluating the accuracy of fine needle aspiration and frozen section based on permanent histology in patients with follicular lesions

Background: Fine needle aspiration (FNA) has led to a decrease in unnecessary surgeries for thyroid nodules. This study was designed to compare diagnostic value of FNA and frozen section methods in the follicular lesions. Methods: This is a cross-sectional study based on the medical records of 42 patients who were referred to surgery clinic of Rasool-e-Akram hospital in Tehran with complain...

متن کامل

The diagnostic value of fine needle aspiration in comparison with frozen section in thyroid nodules: A 20-year study

Background: Fine needle aspiration (FNA) is the most important method in the diagnosis of thyroid nodules before surgery. Recently, the efficiency of FNA in thyroid nodule management has been debatable. On the other hand, intraoperative frozen section (FS) has been used to confirm the diagnosis of FNA and select the proper surgical approach. In this regard, the present study aimed to assess the...

متن کامل

The utility of routine frozen section examination for intraoperative diagnosis of thyroid cancer.

BACKGROUND The value of routine frozen section examination for intraoperative diagnosis of thyroid cancer and determination of extent of thyroidectomy is controversial and needs to be evaluated on an institution to institution basis. METHODS A prospective evaluation of 76 patients with nodular thyroid disease who had an adequate fine needle aspiration biopsy (FNAB) underwent thyroidectomy wit...

متن کامل

The Diagnostic Accuracy of Frozen Section Compared to Permanent Section: A Single Center Study in Iran

Background:The diagnostic accuracy of frozen section as an important source of information in surgical pathology is important not only in the management of surgical patients but also as a measure of quality control in surgical pathology. In this study, we evaluated the diagnostic accuracy of frozen sections over a 6-year period in a teaching hospital in Iran. Methods: We retr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2004