Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography.

نویسندگان

  • O Muzik
  • C Duvernoy
  • R S Beanlands
  • S Sawada
  • F Dayanikli
  • E R Wolfe
  • M Schwaiger
چکیده

OBJECTIVES Regional myocardial blood flow (MBF) and flow reserve measurements using nitrogen-13 (N-13) ammonia positron emission tomography (PET) were compared with quantitative coronary angiography to determine their utility in the detection of significant coronary artery disease (CAD). BACKGROUND Dynamic PET protocols using N-13 ammonia allow regional quantification of MBF and flow reserve. To establish the diagnostic performance of this method, the sensitivity and specificity must be known for varying decision thresholds. METHODS MBF and flow reserve for three coronary territories were determined in 20 normal subjects and 31 patients with angiographically documented CAD by means of dynamic PET and a three-compartment model for N-13 ammonia kinetics. Ten normal subjects defined the normal mean and SD of MBF and flow reserve, and 10 normal subjects were compared with patients. PET flow obtained in the territory with the most severe stenosis in each patient was correlated with the angiographic assessment of the stenosis (severity > or = 50%, > or = 70%, > or = 90%). Receiver operating characteristic (ROC) curve analysis was performed for 1.5, 2.0, 2.5, 3.0 and 4.0 SD of flow abnormalities. RESULTS MBF and flow reserve values from the normal subjects and from territories with documented stenoses > or = 50% were significantly different (p < 0.05). A significant difference was found between normal subjects and angiographically normal territories of patients with CAD. High diagnostic accuracy and sensitivity, with moderately high specificity, were demonstrated for detection of all stenoses. CONCLUSIONS Quantification of myocardial perfusion using dynamic PET and N-13 ammonia provides a high performance level for the detection and localization of CAD. The specificity of dynamic PET was excellent in patients with a low likelihood of CAD, whereas an abnormal flow reserve in angiographically normal territories was postulated to represent early functional abnormalities of vascular reactivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography.

OBJECTIVES The study compared flow reserve indices by magnetic resonance imaging (MRI) with quantitative measures of coronary angiography and positron emission tomography (PET). BACKGROUND The noninvasive evaluation of myocardial flow by MRI has recently been introduced. However, a comparison to quantitative flow measurement as assessed by PET has not been reported in patients with coronary a...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

Assessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.

BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...

متن کامل

Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography.

BACKGROUND Monitoring contrast medium wash-in kinetics in hyperemic myocardium by magnetic resonance (MR) allows for the detection of stenosed coronary arteries. In this prospective study, the quality of a multislice MR approach with respect to the detection and sizing of compromised myocardium was determined and compared with positron emission tomography (PET) and quantitative coronary angiogr...

متن کامل

Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography.

BACKGROUND Recent evidence suggests that the diagnostic accuracy of myocardial perfusion imaging is improved by quantifying stress myocardial blood flow (MBF) in absolute terms. We evaluated a comprehensive quantitative (13)N-ammonia positron emission tomography ((13)NH3-PET) diagnostic panel, including stress MBF, coronary flow reserve (CFR), and relative flow reserve (RFR) in conjunction with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 31 3  شماره 

صفحات  -