Peripheral dose distributions for a linear accelerator equipped with a secondary multileaf collimator and universal wedge

نویسندگان

  • Sasa Mutic
  • Jacqueline Esthappan
  • Eric E. Klein
چکیده

The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distributions and TG-36 reported data. Measurements were performed to evaluate PD distributions for a linear accelerator equipped with a secondary MLC, backup diaphragms, and UW. This data can be used to compliment the TG-36 report for estimation of doses to critical structures outside primary radiation fields. For the evaluated linear accelerator, an MLC is incorporated in the upper secondary collimator jaws. Backup shielding diaphragms are located underneath the MLC. At the nominal collimator position, the MLC and the backup diaphragm provide collimation primarily in the transverse direction. Conventional, solid tungsten-alloy jaws, located underneath the backup diaphragms, provide secondary collimation in the longitudinal direction. The universal wedge provides dose modulation in the direction of the conventional jaws. Measurements were made with an ionization chamber inserted into a 20x40x120 cm(3) water-equivalent plastic phantom with the secondary collimator and MLC settings of 5x5, 10x10, 15x15, and 25x25 cm(2) with and without UW. Data was acquired along the machine's longitudinal axis for 6, 10, and 18 MV photons. Peripheral dose distributions were measured with the collimator rotated to 0 degrees and 270 degrees for open field measurements and to 0 degrees, 180 degrees, and 270 degrees for wedged fields (IEC 1217). This allowed evaluation of peripheral dose distributions as a function of collimator rotation. Wedged fields were normalized to deliver the same dose at the depth of maximum dose on the central axis as open fields. The measured PD distributions were generally comparable to data reported by TG-36. At distances close to the field edge (less than 30 or 40 cm), the measured PD distributions were lower when the measurement point was shielded by solid jaws than with MLC and backup diaphragm. At longer distances, this trend reversed for all energies and evaluated field sizes. However, the difference in PD distribution with collimator rotation was not large enough to warrant strategic positioning of the collimator to reduce dose to critical structures outside the primary radiation field. Because internal scatter dominates close to the field edge, wedged PD distributions were comparable to open field doses at distances closer than 30 cm. However, at distances larger than 30 cm from the field edge, wedged PD distributions were significantly grater than those for open fields due to increased contribution of leakage radiation. Increased leakage radiation is due to the increase in wedged field monitor units, which is related to a small wedge factor (0.27 to 0.29).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation of wedge‐shaped dose distributions through dynamic multileaf collimator dose delivery

A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to the intensity-modulated radiation therapy (IMRT) leaf sequence generation algori...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Radiation therapy treatment planning for many clinical situations requires wedgeshaped isodose distributions. The wedged dose distributions can be generated through the use of physical wedges (PWs), motorized wedges and the synchronization of jaw or multileaf collimator dynamic motion with accelerator dose output. Modern medical accelerators are usually equipped with a dynamic wedge (DW) option...

متن کامل

Use of a multileaf collimator to increase the field width achievable with a dynamic wedge

A method is proposed for generating dynamic wedges spanning the entire field width, defined as the collimator opening in the wedged direction, without changes to existing hardware. The technique approximates the fluence pattern of a dynamic wedge by sequentially closing the leaves of a 120-leaf multileaf collimator (MLC). Closure times for the individual leaves were derived by extending the seg...

متن کامل

Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy

Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...

متن کامل

The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions

Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2002