Development and evaluation of an ultrasonic personal aerosol sampler

نویسندگان

  • J. Volckens
  • C. Quinn
  • D. Leith
  • J. Mehaffy
  • C. S. Henry
  • D. Miller‐Lionberg
چکیده

Assessing personal exposure to air pollution has long proven challenging due to technological limitations posed by the samplers themselves. Historically, wearable aerosol monitors have proven to be expensive, noisy, and burdensome. The objective of this work was to develop a new type of wearable monitor, an ultrasonic personal aerosol sampler (UPAS), to overcome many of the technological limitations in personal exposure assessment. The UPAS is a time-integrated monitor that features a novel micropump that is virtually silent during operation. A suite of onboard environmental sensors integrated with this pump measure and record mass airflow (0.5-3.0 L/min, accurate within 5%), temperature, pressure, relative humidity, light intensity, and acceleration. Rapid development of the UPAS was made possible through recent advances in low-cost electronics, open-source programming platforms, and additive manufacturing for rapid prototyping. Interchangeable cyclone inlets provided a close match to the EPA PM2.5 mass criterion (within 5%) for device flows at either 1.0 or 2.0 L/min. Battery life varied from 23 to 45 hours depending on sample flow rate and selected filter media. Laboratory tests of the UPAS prototype demonstrate excellent agreement with equivalent federal reference method samplers for gravimetric analysis of PM2.5 across a broad range of concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PM0.1 Personal Sampler for Evaluation of Personal Exposure to Aerosol Nanoparticles

A PM0.1 personal sampler devised by the authors (Furuuchi et al., 2010a) was investigated into its performance for the practical application, or on an improvement for a smaller cut-off size and also the removal of coarse particles using pre-cut impactors. The pressure drop through the inertial filter was discussed along with the separation performance since it is important to use a portable bat...

متن کامل

Laboratory evaluation of the CIP 10 personal dust sampler.

The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow th...

متن کامل

Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...

متن کامل

تاثیر وسیله کاهنده آئروسل بر پراکندگی آئروسل های عفونی به هنگام جرمگیری اولتراسونیک

Statement of Problem: Ultrasonic Scaling is one of the main sources of producing infected aerosols in dentistry. These aerosols are able to spread pathogens such as microorganisms associated with tuberculosis, conjunctivitis, influenza and other respiratory diseases, herpetic and other skin diseases, ADIS and hepatitis B.Purpose: The aim of this study was to investigate the clinical effective...

متن کامل

A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.

There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use ...

متن کامل