Opaque Bubble Layer Risk Factors in Femtosecond Laser-assisted LASIK.

نویسندگان

  • Romain Courtin
  • Alain Saad
  • Emmanuel Guilbert
  • Alice Grise-Dulac
  • Damien Gatinel
چکیده

PURPOSE To determine the characteristics and risk factors for occurrence of opaque bubble layer (OBL) during femtosecond laser-assisted flap creation for LASIK. METHODS One hundred ninety-eight eyes of 102 consecutive patients who underwent LASIK flap creation performed with the Alcon WaveLight FS200 laser (Alcon Laboratories, Inc., Fort Worth, TX) were retrospectively analyzed in a cohort study. Preoperative manifest refraction, corneal keratometry, central corneal thickness, white-to-white corneal diameter, corneal hysteresis, corneal resistance factor, and programmed flaps parameters were collected. Digital images automatically recorded after flap creation were analyzed to measure OBL areas. Correlation tests were performed between preoperative corneal parameters and OBL areas. RESULTS The incidence rate of OBL was 48% (103 eyes). The mean OBL area as a percentage of the corneal flap area in the OBL group was 4.25% ± 7.16% (range: 0% to 32.9%). The central corneal thickness, corneal resistance factor, and corneal hysteresis were significantly positively correlated with the OBL area (r = 0.242, P = .001; r = 0.254, P = .028; and r = 0.351, P < .0001, respectively). Corneal hysteresis and OBL area were positively correlated, independently of the central corneal thickness and other confounder factors with standardized coefficient (r = 0.353 ± 0.227, P = .002). CONCLUSIONS This study confirms the already known OBL risk factors with a larger cohort and suggests for the first time that an elevated corneal hysteresis is an independent predictive risk for OBL occurrence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique

BACKGROUND The purpose of this study was to determine flap parameter accuracy, extent of the opaque bubble layer, and incidence of skip lines in femtosecond laser-assisted stromal in situ keratomileusis (LASIK) using the WaveLight(®) FS200 laser and optoelectronic clinical measurements. METHODS Images from 101 flaps were automatically recorded during consecutive routine LASIK procedures perfo...

متن کامل

Femtosecond Laser-Assisted LASIK Flap Complications.

PURPOSE To discuss intraoperative and postoperative femtosecond laser-assisted LASIK flap complications and their management. METHODS Review of published literature. RESULTS Flap creation is a critical step in LASIK. The femtosecond laser has improved the overall predictability and safety of the lamellar incision, but complications can still occur during or after flap creation. Although man...

متن کامل

In vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT.

The authors report in vivo morphology of opaque bubble layers with ultrahigh-resolution anterior-segment optical coherence tomography (UHR-OCT) in 3 patients. Two patients were operated on with a 30-kHz IntraLase femtosecond laser (Abbott Medical Optics, Abbott Park, IL) and one patient was operated on with a 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). UHR-OCT images ...

متن کامل

Essential opaque bubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser

BACKGROUND The purpose of this study is to evaluate the extent and incidence of opaque bubble layer (OBL) using laser-assisted in situ keratomileusis (LASIK) flaps created with the Alcon/WaveLight® FS200 femtosecond laser as a result of a recent change in flap programming parameters aiming to reduce further the incidence and extent of OBL. METHODS Intraoperative digital images of flaps from 3...

متن کامل

Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

Purpose. To report the incidence and outcomes of anterior chamber gas bubble formation during femtosecond laser flap creation for laser-assisted in situ keratomileusis (LASIK). Methods. The charts of 2,886 consecutive eyes that underwent femtosecond LASIK from May 2011 through August 2014 were retrospectively reviewed. The incidence, preoperative characteristics, intraoperative details, and pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 31 9  شماره 

صفحات  -

تاریخ انتشار 2015