Reimplantation and Repeat Infection After Cardiac-Implantable Electronic Device Infections: Experience From the MEDIC (Multicenter Electrophysiologic Device Infection Cohort) Database.

نویسندگان

  • Thomas A Boyle
  • Daniel Z Uslan
  • Jordan M Prutkin
  • Arnold J Greenspon
  • Larry M Baddour
  • Stephan B Danik
  • Jose M Tolosana
  • Katherine Le
  • Jose M Miro
  • James Peacock
  • Muhammad R Sohail
  • Holenarasipur R Vikram
  • Roger G Carrillo
چکیده

BACKGROUND Infection is a serious complication of cardiovascular-implantable electronic device implantation and necessitates removal of all hardware for optimal treatment. Strategies for reimplanting hardware after infection vary widely and have not previously been analyzed using a large, multicenter study. METHODS AND RESULTS The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with cardiovascular-implantable electronic device infections at multiple institutions in the United States and abroad between 2009 and 2012. Reimplantation strategies were evaluated overall, and every patient who relapsed within 6 months was individually examined for clinical information that could help explain the negative outcome. Overall, 434 patients with cardiovascular-implantable electronic device infections were prospectively enrolled at participating centers. During the initial course of therapy, complete device removal was done in 381 patients (87.8%), and 220 of them (57.7%) were ultimately reimplanted with new devices. Overall, the median time between removal and reimplantation was 10 days, with an interquartile range of 6 to 19 days. Eleven of the 434 patients had another infection within 6 months, but only 4 of them were managed with cardiovascular-implantable electronic device removal and reimplantation during the initial infection. Thus, the repeat infection rate was low (1.8%) in those who were reimplanted. Patients who retained original hardware had a 11.3% repeat infection rate. CONCLUSIONS Our study findings confirm that a broad range of reimplant strategies are used in clinical practice. They suggest that it is safe to reimplant cardiac devices after extraction of previously infected hardware and that the risk of a second infection is low, regardless of reimplant timing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Timing of the most recent device procedure influences the clinical outcome of lead-associated endocarditis results of the MEDIC (Multicenter Electrophysiologic Device Infection Cohort).

OBJECTIVES The purpose of this study was to determine whether the timing of the most recent cardiac implantable electronic device (CIED) procedure, either a permanent pacemaker or implantable cardioverter-defibrillator, influences the clinical presentation and outcome of lead-associated endocarditis (LAE). BACKGROUND The CIED infection rate has increased at a time of increased device use. LAE...

متن کامل

Cardiac implantable electronic device infections: presentation, management, and patient outcomes.

BACKGROUND Indications for cardiac implantable electronic devices (CIEDs) are increasing. Although CIED infections occur infrequently, the impact of this outcome is expected to be substantial. OBJECTIVE The purpose of this study was to the evaluate the outcome of patients undergoing removal of infected CIEDs. METHODS A retrospective study was conducted of all patients with proven or suspect...

متن کامل

The wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections

BACKGROUND The approach to treat device infection in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) is a challenging procedure. Optimal treatment is complete extraction of the infected device. To protect these patients from sudden cardiac arrest while waiting for reimplantation and to avoid recurrent infection, a wearable ca...

متن کامل

Frequency of device-associated infections in intensive care units

Background: Health care associated infections (HAIs) are a class of infections that infect patients during hospital admissions and receive medical services. These infections occurs within 48 to 72 hours of admission and up to 6 weeks after discharge. Surveillance of device-associated infections (DAIs) in intensive care units (ICUs) is substantial in planning healthcare strategies. This study wa...

متن کامل

Infected cardiac-implantable electronic devices: prevention, diagnosis, and treatment.

Cardiac implantable electronic device (CIED) infection, according to current trends, appears to be an increasing problem. It can be indolent and its diagnosis challenging. Cardiac implantable electronic device infections are potentially lethal, and timely diagnosis and early initiation of correct treatment are of highest importance for patient prognosis. For reducing CIED infections, careful pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2017