Dose estimation for different skin models in interstitial breast brachytherapy

نویسندگان

  • Judyta Lasota
  • Renata Kabacińska
  • Roman Makarewicz
چکیده

PURPOSE Skin is a major organ at risk in breast-conserving therapy (BCT). The American Brachytherapy Society (ABS) recommendations require monitoring of maximum dose received, however, there is no unambiguous way of skin contouring provided. The purpose of this study was to compare the doses received by the skin in different models. MATERIAL AND METHODS Standard treatment plans of 20 patients who underwent interstitial breast brachytherapy were analyzed. Every patient had a new treatment plan prepared according to Paris system and had skin contoured in three different ways. The first model, Skin 2 mm, corresponds to the dermatological breast skin thickness and is reaching 2 mm into an external patient contour. It was rejected in a further analysis, because of distinct discontinuities in contouring. The second model, Skin 4 mm, replaced Skin 2 mm, and is reaching 2 mm inside and 2 mm outside of the External contour. The third model, Skin EXT, is created on the External contour and it expands 4 mm outside. Doses received by the most exposed 0.1 cc, 1 cc, 2 cc, and the maximum doses for Skin 4 mm and Skin EXT were compared. RESULTS Mean, median, maximum, and standard deviation of percentage dose difference between Skin EXT and Skin 4 mm for the most exposed 0.1 cc (D0.1cc) of skin were 18.01%, 17.20%, 27.84%, and 4.01%, respectively. All differences were statistically significant (p < 0.05). CONCLUSIONS Monitoring of doses received by skin is necessary to avoid complications and obtain a satisfactory cosmetic effect. It is difficult to assess the compatibility of treatment plans with recommendations, while there is no unambiguous way of skin contouring. Especially, if a mean difference of doses between two models of skin contouring is 18% for the most exposed 0.1 cc and can reach almost 28% in some cases. Differences of this magnitude can result in skin complications during BCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation

Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...

متن کامل

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

The Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014