Evaluation of Vitek GNI1 and Becton Dickinson Microbiology Systems Crystal E/NF Identification Systems for Identification of Members of the Family Enterobacteriaceae and Other Gram-Negative, Glucose-Fermenting and Non-Glucose-Fermenting Bacilli
نویسندگان
چکیده
We evaluated the Vitek GNI1 and Becton Dickinson Crystal E/NF identification systems for their ability to accurately identify 619 and 626 strains, respectively, of members of the family Enterobacteriaceae and other glucose-fermenting and non-glucose-fermenting gram-negative rods. All strains tested were taken from a stock collection and passed three times on 5% sheep blood agar prior to testing. These strains represented a more rigorous challenge to both systems than one resulting from the testing of consecutive clinical isolates. Testing with both systems was done according to the manufacturers’ instructions, and tests were repeated in duplicate when errors occurred. Vitek version 5.01 and Crystal version 3.0 softwares were used for identifications. The identification results from each system were compared with identifications previously determined with reference biochemicals. At the completion of the appropriate incubation period, the GNI1 and Crystal systems correctly identified 80.1 and 71.1% of the total isolates, respectively. After additional tests suggested by the software programs were completed, the GNI1 had an accuracy of 87.6% and the Crystal system’s accuracy had improved to 87.9%. The error rates for the GNI1 and Crystal systems were 6.5 and 5.3%, respectively. A report of “no identification” was given for 6.0 and 6.9% of the isolates, respectively, and was associated with no particular organism group. One isolate each of Acinetobacter lwoffii and Vibrio alginolyticus would not grow in the Vitek card. The average times to detection for correct enteric identifications in the GNI1 system were 4.1 and 6.8 h for nonenteric identifications, while the Crystal results were routinely read at 18 h. We conclude that there was no significant difference (P > 0.05) between the results of the GNI1 card and those of the Crystal E/NF system after additional testing was performed with the group of organisms tested, but the overall accuracy for both systems in this study was below 90%.
منابع مشابه
Evaluation of the Vitek 2 ID-GNB assay for identification of members of the family Enterobacteriaceae and other nonenteric gram-negative bacilli and comparison with the Vitek GNI+ card.
We evaluated the Vitek 2 ID-GNB identification card (bioMérieux, Inc., Durham, N.C.) for its ability to identify members of the family Enterobacteriaceae and other gram-negative bacilli that are isolated in clinical microbiology laboratories. Using 482 enteric stock cultures and 103 strains of oxidase-positive, gram-negative glucose-fermenting and nonfermenting bacilli that were maintained at -...
متن کاملAbility of the MicroScan rapid gram-negative ID type 3 panel to identify nonenteric glucose-fermenting and nonfermenting gram-negative bacilli.
The MicroScan Rapid Neg ID3 panel is designed for the identification of Enterobacteriaceae and nonenteric glucose-fermenting and nonfermenting gram-negative bacilli. We evaluated this panel for its ability to identify gram-negative non-Enterobacteriaceae bacteria. A total of 134 strains, representing 26 genera and 42 species, were taken from storage at -70(o)C, passaged three times before testi...
متن کاملDiscrimination of Enterobacteriaceae and Non-fermenting Gram Negative Bacilli by MALDI-TOF Mass Spectrometry
Discrimination of Enterobacteriaceae and Non-fermenting Gram Negative Bacilli by MALDI-TOF Mass Spectrometry Matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) has proven to be an effective identification tool in medical microbiology. Discrimination to subspecies or serovar level has been found to be challenging using commercially available identificatio...
متن کاملMolecular Identification of ESBLs Genes (blaTEM, blaSHV and blaCTX) among Non-fermenting Gram-negative Bacteria Isolated from Hospitalized Patients in Mazandaran Province, Iran
Background and purpose: Production of beta-lactamase enzymes by bacteria, especially Extended-spectrum β-lactamases (ESBLs) is one of the major problems worldwide. ESBLs are mostly located on bacterial plasmids and it is recognized that SHV, TEM, and CTX-M are prevailing among them. The aim of this study was to determine the ability to produce ESBLs genes based on molecular method among non-fer...
متن کاملEvaluation of the VITEK 2 system for rapid identification of medically relevant gram-negative rods.
The new VITEK 2 system (bioMérieux) was evaluated at two independent sites with the identification card for gram-negative bacilli (ID-GNB card). Of the 845 strains tested, which represented 70 different taxa belonging to either the family Enterobacteriaceae or the nonenteric bacilli, 716 (84.7%) were correctly identified at the species level. Thirty-two (3.8%) additional strains were identified...
متن کامل