Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh

نویسندگان

  • Farzaneh Sharifiaghdas
  • Azar Daneshpajooh
  • Mahboubeh Mirzaei
چکیده

PURPOSE To evaluate the medium-term efficacy and safety of transobturator four-arm polypropylene mesh in the treatment of high-stage anterior vaginal wall prolapse and concomitant stress urinary incontinence (SUI). MATERIALS AND METHODS Between September 2010 and August 2013, a prospective single-center trial was performed to evaluate women with stage≥3 anterior vaginal wall prolapse with or without SUI who presented to Labbafinejad Hospital, Teheran, Iran, and underwent anterior vaginal wall repair with polypropylene mesh. Pre- and postoperative evaluation included history; physical examination using the Pelvic Organ Prolapse Quantification system and cough stress test, both before and after reduction of prolapsed structures; Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ); urinalysis and culture; and a postvoid residual assessment. Complications were reported at a mean of 2 years of follow-up. RESULTS A total of 71 patients underwent cystocele repair with the transobturator four-arm polypropylene mesh. Seven of the patients were lost to follow-up. There were no perioperative complications. The anatomical success rate was 87.5%. The subjective success rate was 92.1%. The PFDI and PFIQ were significantly improved after surgery (p<0.001). Among those with the simultaneous complaint of SUI, 82% were cured without any additional procedure. Three patients (4.6%) experienced vaginal mesh extrusion. Two patients (3.1%) reported worsening of dyspareunia after surgery. CONCLUSIONS The four arms polypropylene mesh is an effective device for simultaneous correction of anterior vaginal wall prolapse and SUI with a low complication rate at a medium-term follow-up. The majority of the subgroup with concomitant SUI were cured without a second simultaneous procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter to the editor: Comment on "Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh"

We have read the article by Sharifiaghdas et al. [1], which was an interesting study that both investigated the safety and efficacy of the four-arm polypropylene mesh (Nazca-Tc, Promedon, Cordoba, Argentina) in the treatment of high-stage cystocele and evaluated clinical outcomes in a subgroup of patients with simultaneous stress urinary incontinence (SUI) via a double transobturator approach. ...

متن کامل

The authors reply: Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh.

To the editor: We greatly appreciate the interest in our work as commented on in your journal. In our article published in the Korean Journal of Urology in 2015 [1], we concluded that the Nazca-Tc system is effective and safe in the treatment of advanced anterior vaginal wall prolapse with a low rate of complications after medium-term follow-up. One of our study limitations was sexual inactivit...

متن کامل

Outcome of Treatment of Anterior Vaginal Wall Prolapse and Stress Urinary Incontinence with Transobturator Tension-Free Vaginal Mesh (Prolift) and Concomitant Tension-Free Vaginal Tape-Obturator

Objective. It is to assess the feasibility, effectiveness, and safety of transobturator tension-free vaginal mesh (Prolift) and concomitant tension-free vaginal tape-obturator (TVT-O) system as a treatment of female anterior vaginal wall prolapse associated with stress urinary incontinence (SUI). Patients and Methods. Between December 2006 and July 2007, 20 patients with anterior genital prolap...

متن کامل

Obturator foramen dissection for excision of symptomatic transobturator mesh.

PURPOSE Groin pain after transobturator synthetic mesh placement can be recalcitrant to conservative therapy and ultimately requires surgical excision. We describe our experiences with and technique of obturator foramen dissection for mesh excision. MATERIALS AND METHODS The records of 8 patients treated from 2005 to 2010, were reviewed. Obturator dissection was performed via a lateral groin ...

متن کامل

Vaginal mesh extrusion associated with use of Mentor transobturator sling.

OBJECTIVES To describe my experience of vaginal mesh extrusion using the monofilament polypropylene transobturator sling, the Mentor ObTape. The Mentor ObTape was the first transobturator sling developed as an alternative to the retropubic commercially available suburethral slings for providing mid-urethral support as treatment of female stress urinary incontinence. METHODS Thirty patients un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2015