Computer-Aided Detection and Diagnosis in Mammography

نویسندگان

  • Mehul P. Sampat
  • Mia K. Markey
  • Alan C. Bovik
چکیده

Screening mammography is the most effective tool for early detection of breast cancer. In this procedure, radiologists scan x-ray images of the breast to locate signs of breast cancer. However it is not perfect and has low sensitivity for detection and low specificity for diagnosis. Various computer aided detection (CAD) and diagnosis (CADx) systems have been developed to aid radiologists. In this paper, we present two studies aimed at improving the performance of existing CAD and CADx algorithms. In the first study, we present a novel evidence based, stage-one algorithm for the detection of spiculated masses (SM) and architectural distortions (AD). By evidence based, we mean that we use the statistics of the physical characteristics of these abnormalities to determine the parameters of the detection algorithm. Each parameter of the algorithm has been incorporated to capture the variation in physical characteristics of SM and AD. The second study is aimed at improving the performance of current diagnosis systems by combining information from multiple views. It is designed to look at the correspondence of features from multiple views. It tires to address the fundamental issue of whether using data from multiple views can really provide additional insight to the diagnosis problem. INTRODUCTION & BACKGROUND: The American Cancer Society estimates that 211,240 women will be diagnosed with breast cancer in the U.S. in 2005. In the US, breast cancer is the most common form of cancer among women and is the second leading cause of cancer deaths, after lung cancer . Early detection of breast cancer increases the survival rate and increases the treatment options. Screening mammography, x-ray imaging of the breast, is currently the most effective tool for early detection of breast cancer. Screening mammographic examinations are performed on asymptomatic woman to detect early, clinically unsuspected breast cancer. Two views of each breast are recorded; the craniocaudal (CC) view, which is a top to bottom view, and a mediolateral oblique (MLO) view, which is a side view taken at an angle. Examples of the MLO and CC views are shown in Figure 1. Radiologists visually search mammograms for specific abnormalities. Some of the important signs of breast cancer that radiologists look for are clusters of microcalcifications, masses, and architectural distortions. A mass is defined as a space-occupying lesion seen in at least two different projections. Calcifications are tiny deposits of calcium, which appear as small bright spots on the mammogram. Architectural distortions are defined as follows, “The normal architecture is distorted with no definite mass visible”. A typical example of each of these abnormalities is shown in Figure 2. Breast lesions are described in terms of their shape, margin and distribution characteristics. These characteristics are reported according to the Breast Imaging Reporting and Data System (BIRADSTM) . BI-RADSTM is a mammography lexicon developed by the American College of Radiology (ACR), for the description of mammographic lesions. Figure 1. The craniocaudal (CC) view (left) and a mediolateral oblique (MLO) view (right). Early detection via mammography increases breast cancer treatment options and the survival rate. However, mammography is not perfect. Detection of suspicious abnormalities is a repetitive and fatiguing task. As a result, radiologists fail to detect 10-30% of cancers, approximately two-thirds of which are evident retrospectively. Mammography has a positive predictive value (PPV) of less than 35% , where the PPV is PhD Candidate, The University of Texas at Austin, Department of Biomedical Engineering PhD Student, The University of Texas at Austin, Department of Electrical and Computer Engineering Assisstant Professor, The University of Texas at Austin, Department of Biomedical Engineering 4 Professor, The University of Texas at Austin, Department of Electrical and Computer Engineering defined as the percentage of lesions subjected to biopsy that were found to be cancer. Thus, a high proportion of biopsies are performed on benign lesions. Avoiding benign biopsies would spare women anxiety, discomfort, and expense. Computer-Aided Detection (CAD) systems have been developed to aid radiologists in detecting mammographic lesions that may indicate the presence of breast cancer. These systems act only as a second reader and the radiologist makes the final decision. Recent studies have also shown that CAD detection systems, when used as an aid, have improved radiologists’ accuracy of detection of breast cancer . Computer-Aided Diagnosis (CADx) systems for aiding in the decision between follow-up and biopsy are still in development. CAD/CADx systems either use features extracted by human observers (e.g. BIRADSTM descriptors) or features extracted directly from digitized/digital mammograms using image processing techniques (e.g. texture features, statistical moments). Figure 2. Examples of a spiculated mass (left), cluster of microcalcifications (center), and architectural distortion (right). The paper describes two studies related to CAD/CADx of breast cancer using mammography images. The first one is a novel technique for the automatic detection of spiculated masses and architectural distortions. The second studies the correspondence between human extracted BI-RADSTM features and computer extracted image texture features. This information would be useful in designing classifiers that use information from both views for diagnosis of lesions. MATERIALS: The images for the studies described in this paper were obtained from the Digital Database for Screening Mammography (DDSM). The DDSM is the largest publicly available data-set of digitized mammograms. It contains 2620 cases acquired from multiple medical institutions. A. Evidence-based detection of spiculated masses and architectural distortions Purpose: The purpose of this study was to develop a new method for the detection of spiculated masses (SM) and architectural distortions (AD) based on their physical characteristics. Motivation: We focused on the detection of SM and AD for a number of reasons. SM carry a much higher risk of malignancy than calcifications or other types of masses. About 81% of SM and 48-60% of AD are malignant . It is estimated that 12-45% of cancers missed in mammographic screening are AD . The detection sensitivity of the current CAD systems for SM and AD is low and there is a pressing need for improvements in their detection. Methods: Most mass detection algorithms consist of two stages. The aim of the first stage is to detect all potential masses. In the second stage, the aim is to reduce the false-positives by classifying the detected masses as true masses or normal tissue. Our stage-one algorithm consists of two steps, an enhancement step followed by a filtering step. In the first step, we propose a new technique for the enhancement of spiculations in which a linear filter is applied to the Radon transform of the image. The filter parameters were set based on measurements made on a set of spiculated masses. The width of spiculations was measured manually by a graduate student and an experienced radiologist. In the second step, we filtered the enhanced images with a new class of linear image filters called ‘Radial Spiculation Filters’. Two such filter-banks are shown in the Figure 3. We have invented these filters specifically for detecting spiculated masses and architectural distortions characterized by converging lines or spiculations. A key aspect of this work is that each parameter of the filter has been incorporated in the filter design to capture the great variation in the physical characteristics of spiculated masses and architectural distortions. To evaluate the performance of the detection algorithm, two sets of images were Figure 3: Radial Spiculation Filters: A new class of filters we have developed for the detection of SM and AD. The figures above show two sets of filter-banks for specific parameter values. used. One set contained 45 images with SM and the other set contained 45 images with AD. These images were scanned with a single digitizer and contained a single lesion and were randomly selected. Results: The detection results of the algorithm are shown in Figure 4. This figure shows the FROC curves for the detection of spiculated masses and architectural distortions. We achieved a sensitivity of 78% at 10 FPI for architectural distortions and 98% at 14 FPI for spiculated masses. These results are competitive with existing stage-one algorithms. We are also developing a stage-two algorithm to reduce the number of FPI. Fig. 4 FROC curves for the stage-one detection algorithm. New or breakthrough work: To the best of our knowledge, no prior studies have attempted to use the statistics of the physical characteristics of spiculated masses and architectural distortions to guide the design and development of a detection algorithm. Conclusions: A new evidence based method was developed for stage one of the detection of spiculated masses and architectural distortions. Further details can be found in . B. Correspondence in BI-RADSTM Descriptors and Texture Features between Mammographic ViewsPurpose: The purpose of this study was to assess the agreement of human extracted BI-RADSTM lesiondescriptors from the MLO and CC mammographic views. The correlation between image texture featuresderived from the two views was also studied.Motivation: Radiologists routinely use multiple mammographic views for detection and diagnosis. Thisimproves performance relative to using a single view. It is likely that CAD/CADx algorithms could alsobenefit from the use of information from multiple views. However, it would be redundant to use twomammographic views in CAD/CADx if they provide the same information. This provides the motivation tostudy the correspondence between features from the MLO and CC views of the breast.Methods: Using kappastatistics, the amount of variation in the reported categories of the BI-RADSTMdescriptors, BI-RADSTM assessment, and subtlety ratings for the two views was assessed for 1626 cases fromthe DDSM. This analysis was stratified by lesion type, pathology outcome, and institutional source of data.Mass cases with low agreement between views were identified. These were used to design linear discriminantanalysis (LDA) based classifiers that combined BI-RADSTM information from the two views. The impact of theaddition of patient age as a feature on the classifier performance was also assessed.The correlation between thirteen Haralick’s texture features extracted from the MLO and CCmammographic views of breast lesions was also studied. Features were ranked on the basis of correlationvalues. The two-view correlation of features for masses was compared against that for calcifications. A similarcomparison was done for benign and malignant lesions.Results: The agreement between the BI-RADSTM descriptors from the two views was consistently higher forcalcifications as compared to masses. The agreement also depended on the institutional source of the datapresumably due to differences in interpretation of instruction given to read mammograms at the differentinstitutions. A classifier that used patient age and averaged the results of two LDA classifiers trained separatelyon the MLO and the CC views displayed the best performance with the highest area under the ROC curve(AUC ± SD = 0.927 ± 0.026). This is depicted as the classifier AVERAGE in Figure 5.Correlation coefficient values of texture features from the two views varied from 0.4 to 0.8. Of thethirteen texture features some were more correlated than the others. Significant differences were found betweenthe correlation of Haralick’s texture features from the two views for different lesion types and lesionpathologies. It was observed that the texture features from the MLO and CC views were less strongly correlatedfor calcification lesions than for mass lesions. Similarly, texture features from the two views were less stronglycorrelated for benign lesions than for malignant lesions. New or Breakthrough work: This study is novel in the sense that it addressed for the first time the question ofwhether an additional mammographic view really adds to information from the existing view or is merely areplication of it’s information. This is fundamental in building CADx systems based on multi-view information.Conclusions: The correspondence studies suggest thatcombining dissimilar information from multiplemammographic views may hold potential to improve theperformance of CADx systems.CONCLUSIONS: In this paper we have summarized thework carried out in the area of CAD and CADx at theLaboratory for Image and Video Processing(www.live.ece.utexas.edu) and the Biomedical InformaticsLaboratory (www.bme.utexas.edu/research/informatics/). Itis important to realize that mammographic image analysis isan extremely challenging task for a number of reasons.First, since the efficacy of CAD/CADx systems can havevery serious implications, there is a need for nearperfection. Second, the large variability in the appearance ofabnormalities makes this a very difficult image analysistask. Finally, abnormalities are often occluded or hidden indense breast tissue, which makes detection difficult. We arecurrently working on the improving the CAD and CADxalgorithms we have developed.Figure 5: ROC curves depicting theperformance of the classifiers MLO (with age),MAXIMUM (with age), AVERAGE (with age)and BOTH (with age).REFERENCES1 American Cancer Society, Cancer Facts and Figures,2005.M. Heath et al., The Digital Database for Screening Mammography, presented at the 5th InternationalWorkshop on Digital Mammography, Toronto, Canada, 2000.American College of Radiology, ACR BI-RADS Mammography, Fourth ed. (American College of Radiology,Reston, VA, 2003).C. H. Lee, Screening mammography: proven benefit, continued controversy, Radiologic clinics of NorthAmerica 40, 395 (2002).T. M. Kolb et al., Comparison of the performance of screening mammography, physical examination, andbreast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations.[seecomment], Radiology 225 (1), 165 (2002).M. L. Giger, Computer-aided diagnosis in radiology, Academic Radiology 9, 1 (2002).D. B. Kopans, The positive predictive value of mammography, AJR. American Journal of Roentgenology 158(3), 521 (1992).M. L. Giger et al., Computer-aided diagnosis in medical imaging, IEEE Transactions on Medical Imaging 20(12), 1205 (2001).L. Liberman et al., The breast imaging reporting and data system: positive predictive value of mammographicfeatures and final assessment categories, AJR. American Journal of Roentgenology. 171 (1), 35 (1998).J. A. Baker et al., Computer-aided detection (CAD) in screening mammography: sensitivity of commercialCAD systems for detecting architectural distortion, AJR. American Journal of Roentgenology. 181 (4), 1083(2003).H. Burrell et al., False-negative breast screening assessment. What lessons can we learn? Clinical Radiology56 (5), 385 (2001).M. P. Sampat et al., Evidenced-based detection of spiculated masses and architectural distortions, presented atthe SPIE Medical Imaging, San Diego, CA, 2005.R. G. Blanks et al., Observer variability in cancer detection during routine repeat (incident) mammographicscreening in a study of two versus one view mammography, Journal of Medical Screening 6 (3), 152 (1999).B. B. A. Rosner, Fundamentals of biostatistics, 5th ed. ed. (Duxbury, Pacific Grove, CA, 2000).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hierarchical Classification Method for Breast Tumor Detection

Introduction Breast cancer is the second cause of mortality among women. Early detection of it can enhance the chance of survival. Screening systems such as mammography cannot perfectly differentiate between patients and healthy individuals. Computer-aided diagnosis can help physicians make a more accurate diagnosis. Materials and Methods Regarding the importance of separating normal and abnorm...

متن کامل

A review of neural network detection methods for breast cancer: review article

Breast cancer is the most common cancer among women and the earlier it is diagnosed, the easier it is to treat. The most common way to diagnose breast cancer is mammography. Mammography is a simple chest x-ray and a tool for early detection of non-palpable breast cancers and tumors. However, due to some limitations of this method such as low sensitivity especially in dense breasts, other method...

متن کامل

DIAGNOSIS OF BREAST LESIONS USING THE LOCAL CHAN-VESE MODEL, HIERARCHICAL FUZZY PARTITIONING AND FUZZY DECISION TREE INDUCTION

Breast cancer is one of the leading causes of death among women. Mammography remains today the best technology to detect breast cancer, early and efficiently, to distinguish between benign and malignant diseases. Several techniques in image processing and analysis have been developed to address this problem. In this paper, we propose a new solution to the problem of computer aided detection and...

متن کامل

Computer Aided Detection on Mammography

A typical definition of the Computer Aided Diagnosis (CAD), found in literature, can be: A diagnosis made by a radiologist using the output of a computerized scheme for automated image analysis as a diagnostic aid. Often it is possible to find the expression Computer Aided Detection (CAD or CADe): this definition emphasizes the intent of CAD to support rather than substitute the human observer ...

متن کامل

Computer Aided Mammography

This research investigated the state of art of computer aided detection systems for digital mammograms, and evaluated the related techniques in image pre-processing, feature extraction and classification of digital mammograms. Furthermore, this paper explored the further research directions for next generation CAD for mammograms. It was identified that computer-aided detection techniques for ma...

متن کامل

Computer-aided detection and diagnosis of breast cancer.

The use of computer-aided detection (CAD) with film or digital mammography is now widely regarded as the standard of practice in mammography and has been shown to increase the rate of breast cancer detection. There are inherent limitations in 2D mammography, and new technologies involving 2D and 3D imaging with X-rays, ultrasound, and MRI are in use or under investigation. CAD can aid in the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005