Routine use of bioprosthetic mesh is not necessary: a retrospective review of 100 consecutive cases of intra-abdominal midweight polypropylene mesh for ventral hernia repair.

نویسندگان

  • Bryan K Richmond
  • Benny Chong
چکیده

BACKGROUND The Ventral Hernia Working Group (VHWG) recently proposed a grading system to assist surgeons in selecting the appropriate mesh based on an individual patient's risk of developing a postoperative complication. The VHWG grading scale was used to evaluate the incidence of surgical-site complications in 100 consecutive midline ventral hernias repaired with uncoated mid-weight polypropylene mesh. METHODS A retrospective review was conducted of 100 consecutive cases of midline ventral hernia repair using an intra-abdominal mesh underlay between July 2005 and May 2010. The median duration of follow-up was 23 months. RESULTS Using the VHWG scale, 50 percent of cases were considered grade 2 ("Co-morbid") and 28 percent considered Grade 3 ("Potentially Contaminated"). The remaining cases were Grade 1 ("Low-risk"). Overall, there was a 5.6 percent rate of hernia recurrence, with a mean time to recurrence of 17 months. There were no enterocutaneous fistulae or infections requiring mesh removal. CONCLUSION The use of uncoated mid-weight polypropylene mesh for reinforcement of midline ventral hernia repairs was not associated with increased rates of infection, fistula formation, or clinically significant adhesions. These findings challenge the recommendation by the VHWG to avoid synthetic repair material in patients with comorbidities or in "potentially contaminated" fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abstract: Reliable Complex Abdominal Wall Hernia Repairs with a Narrow Well-Fixed Retrorectus Polypropylene Mesh: A Review of over 100 Consecutive Cases

BACKGROUND Our objective was to determine outcomes for complex ventral hernia repairs in a large cohort of patients utilizing an operative construct employing retrorectus placement of a narrow, macroporous polypropylene mesh with up to 45 suture fixation points for force distribution. No consensus exists on the optimal technique for repair of complex ventral hernias. Current trends emphasize la...

متن کامل

A retrospective analysis of surgical treatment of mesh infection after repair of ventral hernia or defect.

This study aimed to summarize our experience in surgical treatment of mesh infection after repair of ventral hernia or defect. A retrospective analysis was conducted on clinical data of 22 patients who accepted surgical treatment of mesh infection after ventral hernia or defect repair. Included were 16 cases of infection after incisional hernia repair, 5 cases of infection after abdominal wall ...

متن کامل

Efficacy of Polypropylene Mesh Coated with Bioresorbable Membrane (Sepramesh) for the Repair of Abdominal Wall Defects in Horses

Objective: The aim of this study was to compare the use of Polypropylene mesh (Prolene) and Sepramesh, a coated Polypropylene mesh with a protective layer of Seprafilm on its visceral side, for the repair of abdominal wall defects in horses. We also aimed to quantify the consequent visceral adhesion and tissue inflammatio Design: Experimental study. Animals: Ten horses. Methods: The horses w...

متن کامل

Repair of recurrent hernia after biologic mesh failure in abdominal wall reconstruction.

BACKGROUND Biologic mesh is commonly used in abdominal wall reconstruction but may result in increased hernia recurrence. There are minimal data on repair of these recurrent hernias. METHODS We conducted a retrospective chart review of 24 patients presenting to a single surgeon with recurrent ventral hernia, previously repaired with biologic mesh. RESULTS Seventeen of 24 study patients unde...

متن کامل

In Vivo Evaluation of a Novel Mesh Suture Design for Abdominal Wall Closure

BACKGROUND The authors present a novel mesh suture design aimed at minimizing the early laparotomy dehiscence that drives ventral hernia formation. The authors hypothesized that modulation of the suture-tissue interface through use of a macroporous structure and increased aspect ratio (width-to-height ratio) would decrease the suture pull-through that leads to laparotomy dehiscence. METHODS I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Surgery

دوره 153 5  شماره 

صفحات  -

تاریخ انتشار 2013