Comparisons between Membrane, Bridge and Cantilever Miniaturized Resistive Vacuum Gauges
نویسندگان
چکیده
Using bulk micromachining, meander-shaped resistor elements consisting of 20 nm Cr and 200 nm Au were fabricated on 1 μm thick silicon nitride membranes, bridges, and cantilevers. The resistance change as a function of pressure depends strongly on the thermal resistance of the two metal lines connecting the heated resistor to the silicon bulk (cold junction) and on the thermal resistance of the silicon nitride. Relative resistance changes ranging from about 3% (small membrane) to 20% (bridge) per mW of input power were obtained when operating the devices in constant voltage mode. The pressure where maximum sensitivity of these gauges occurs depends on the distance 'd' between the periphery of the heated resistor element and the silicon cold junction. Devices with 'd' ranging from 50 μm to 1,200 μm were fabricated. Assuming that pressures can be reliably measured above the 10% and below the 90% points of the resistance versus pressure curve, the range of these devices is about two orders of magnitude. By integrating two devices, one with d = 65 μm and one with d = 1,200 μm on the same chip and connecting them in series, the range can be increased by about a factor of three. By fabricating the cantilever devices so that they curl upon release, it will be shown that these devices also exhibit larger range due to varying 'd'.
منابع مشابه
Miniaturized Wide-Range Field-Emission Vacuum Gauge Short Communication
Miniaturized vacuum gauges (MVGs) for the measurement range 5.7x10-7 to 1.1x10-2 mbar were fabricated in a selfaligned approach using focused ion beam (FIB) nanoma‐ chining and reactive ion etching (RIE). The MVG consists of two properly insulated electrodes integrated on top of an atomic force microscopy (AFM) tip, forming a coaxial embodiment. The special design enables us to vary the cathode...
متن کاملStress-Strain Field and Theoretical Analysis of RC Bridge
In this paper, a reinforced concrete(RC) bridge built in an interchange, in the city of Kerman (a city located in south of Iran) is examined by the Structural Health Monitoring (SHM) system. During the construction of this bridge such as; the main beams, slab, and retaining walls, some Electrical Strain Gauges were mounted on the main reinforcements at different locations within the body of thi...
متن کاملIon Implantation with Scanning Probe Alignment
We describe a scanning probe instrument which integrates ion beams with the imaging and alignment function of a piezo-resistive scanning probe in high vacuum. The beam passes through several apertures and is finally collimated by a hole in the cantilever of the scanning probe. The ion beam spot size is limited by the size of the last aperture. Highly charged ions are used to show hits of single...
متن کاملComparisons of Experimental and Simulated Velocity Fields in Membrane Module Spacers
Spacers are used in spiral wound and plate and frame membrane modules to create flow channels between adjacent membrane layers and mix fluid within the flow channel. Flow through the spacer has a significant beneficial impact on mixing and resulting mass transfer rates but is accompanied by an undesirable increase in pressure drop. Computational Fluid Dynamics (CFD) is a common tool used to eva...
متن کاملTowards SU(2) invariant formulation of the monopole confinement mechanism
The type of the vacuum is studied numerically in the maximally Abelian (MA) gauge and in the Landau (LA) gauge of SU(2) gluodynamics. The type of the vacuum is determined by a ratio between the dual coherence and the dual penetration lengths. The dual penetration length is determined from correlations between Wilson loops and electric fields in both gauges. The dual coherence length is found fr...
متن کامل