Abnormalities of chromatic and luminance critical flicker frequency in multiple sclerosis.
نویسندگان
چکیده
Critical flicker frequency (CFF) was measured for stimuli varying in chromaticity only and in luminance only for patients with multiple sclerosis (MS) and for matched normal controls. The two CFF measurements showed different underlying linear interdependencies for the two groups, consistent with a greater loss of temporal luminance function than of temporal chromatic function in MS patients. These results are discussed in relation to the pathophysiology of demyelinated nerve fibers. It is suggested that demyelination affects all types of nerve fiber unselectively; in particular, no support is found for the notion of a special vulnerability of fibers carrying time-varying chromatic information.
منابع مشابه
Multiple sclerosis. Luminance threshold and measurements of temporal characteristics of vision.
Luminance threshold, perceptual latency, double-flash resolution, and critical flicker frequency were examined in patients with multiple sclerosis (MS) and in normal control subjects. The intensities of the stimuli used to test the temporal properties of vision were equalized with respect to individual luminance thresholds. In eight patients with MS, all the properties tested showed abnormality...
متن کاملSensitivity of macaque retinal ganglion cells to chromatic and luminance flicker.
1. We have studied the sensitivity of macaque retinal ganglion cells to sinusoidal flicker. Contrast thresholds were compared for stimuli which alternated only in luminance ('luminance flicker') or chromaticity ('chromatic flicker'), or which modulated only the middle- or long-wavelength-sensitive cones ('silent substitution'). 2. For luminance flicker, the lowest thresholds were those of phasi...
متن کاملDelayed cone-opponent signals in the luminance pathway.
Cone signals in the luminance or achromatic pathway were investigated by measuring how the perceptual timing of M- or L-cone-detected flicker depended on temporal frequency and chromatic adaptation. Relative timings were measured, as a function of temporal frequency, by superimposing M- or L-cone-isolating flicker on "equichromatic" flicker (flicker of the same wavelength as the background) and...
متن کاملChromatic adaptation alters spectral sensitivity at high temporal frequencies.
To evaluate the effects of chromatic adaptation on spectral sensitivity at temporal frequencies within the region of high-frequency linearity, critical flicker frequency was measured as a function of red-green luminance ratio for counterphase flicker of 649- and 555-nm light. For eight observers, the relative weight of the contribution of the long-wavelength-sensitive cones to flicker detection...
متن کاملNonselective losses in foveal chromatic and luminance sensitivity in multiple sclerosis.
A psychophysical technique involving simple increment threshold measurements was used to determine foveal chromatic and luminance sensitivity in patients with multiple sclerosis (MS) and in matched normal controls. The patient group showed substantial and nonselective losses in chromatic and luminance sensitivity relative to the normal control group, and these losses were significantly correlat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 23 2 شماره
صفحات -
تاریخ انتشار 1982