A new hybrid (hydro-numerical) model of the circulatory system

نویسندگان

  • M. DAROWSKI
  • M. KOZARSKI
  • G. FERRARI
  • K. ZIELIŃSKI
  • K. GÓRCZYŃSKA
  • A. SZCZEPANOWSKI
  • K. J. PAŁKO
  • L. FRESIELLO
  • A. DI MOLFETTA
چکیده

The paper presents a hybrid (hydro-numerical) circulatory model built to be used as a complementary tool for clinical purposes. It was developed at the Institute of Biocybernetics and Biomedical Engineering – Polish Academy of Sciences (Poland) in co-operation with the Institute of Clinical Physiology – National Council of Research (Italy). Main advantages of the model are: 1) high accuracy and repeatability of parameters setting, characteristic of numerical solutions, 2) maximum flexibility achieved by implementing the largest possible number of the model’s elements in the numerical way, 3) ability to test mechanical heart assist devices provided by special computer applications; in the model two physically different signal environments – numerical and hydraulic – are connected by special impedance transformers interfacing physical and numerical parts of the model; 4) eliminating flowmeters, as the voltage controlled flow sources embedded in the system provide information on flows. In vitro tests were performed to evaluate the circulatory model: a) modelling and simulation of physiological and pathological states parameters vs. left ventricular end-systolic elastance (Emax l) and rest volume (V ol) variations, b) testing the effect of LVAD counterpulsation on circulatory hemodynamics and ventricular energetics; it resulted in the increase of total cardiac output (COLV tot) from pathological value 3.8 to 5.4 l·min, mean aortic pressure mPas from 67.8 to 96.1 mmHg and in the decrease of left atrial pressure mPla from 15.7 to 7.7 mmHg and External Work nEW by 37.5%. The model was verified based on literature data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Minimum Order Lumped-Parameter Model of Circulatory System for Patients with Suffered Left and Right-Sided Heart Failure

In this study a new minimum lumped electrical model of total circulatory system through numerical solutions to approximate the response of the human circulatory system was presented. Among five existent ventricular elastances as activity function of heart pumps, a more accurate model was chosen as well as the operation of baroreflex system to accommodate variations in heart rate and systemic va...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Fuel consumption optimization of a series hybrid electric vehicle utilizing ‎fuzzy logic control

The controller of the hybrid electric vehicle determines the combustion engine start-stop time, the operation points, and regenerative brake energy. The Controlling approach of hybrid electric vehicles controls the amount of needed fuel in every driving situation. In the present study, the thermostat strategy is implemented along with fuzzy logic control and compared to the classic thermostat s...

متن کامل

Nonresonant Excitation of the Forced Duffing Equation

We investigate the hard nonresonant excitation of the forced Duffing equation with a positive damping parameter E. Using the symbolic manipulation system MACSYMA, a computer algebra system. we derive the two term perturbation expansion by the method of multiple time scales. The resulting approximate solution is valid for small values of the coefficient e As the damping parameter e increases, th...

متن کامل

Hybrid Simulation of a Frame Equipped with MR Damper by Utilizing Least Square Support Vector Machine

In hybrid simulation, the structure is divided into numerical and physical substructures to achieve more accurate responses in comparison to a full computational analysis. As a consequence of the lack of test facilities and actuators, and the budget limitation, only a few substructures can be modeled experimentally, whereas the others have to be modeled numerically. In this paper, a new hybrid ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014