Accurate Modeling of The Siemens S7 SCADA Protocol For Intrusion Detection And Digital Forensic
نویسندگان
چکیده
The Siemens S7 protocol is commonly used in SCADA systems for communications between a Human Machine Interface (HMI) and the Programmable Logic Controllers (PLCs). This paper presents a model-based Intrusion Detection Systems (IDS) designed for S7 networks. The approach is based on the key observation that S7 traffic to and from a specific PLC is highly periodic; as a result, each HMI-PLC channel can be modeled using its own unique Deterministic Finite Automaton (DFA). The resulting DFA-based IDS is very sensitive and is able to flag anomalies such as a message appearing out of its position in the normal sequence or a message referring to a single unexpected bit. The intrusion detection approach was evaluated on traffic from two production systems. Despite its high sensitivity, the system had a very low false positive rate over 99.82% of the traffic was identified as normal.
منابع مشابه
Accurate Modeling of the Siemens S7 SCADA Protocol for Intrusion Detection and Digital Forensics
The Siemens S7 protocol is commonly used in SCADA systems for communications between a Human Machine Interface (HMI) and the Programmable Logic Controllers (PLCs). This paper presents a model-based Intrusion Detection Systems (IDS) designed for S7 networks. The approach is based on the key observation that S7 traffic to and from a specific PLC is highly periodic; as a result, each HMI-PLC chann...
متن کاملTowards a SCADA Forensics Architecture
With the increasing threat of sophisticated attacks on critical infrastructures, it is vital that forensic investigations take place immediately following a security incident. This paper presents an existing SCADA forensic process model and proposes a structured SCADA forensic process model to carry out a forensic investigations. A discussion on the limitations of using traditional forensic inv...
متن کاملA Statechart-Based Anomaly Detection Model for Multi-Threaded SCADA Systems
SCADA traffic between the Human Machine Interface (HMI) and the Programmable Logic Controller (PLC) is known to be highly periodic. However, it is sometimes multiplexed, due to asynchronous scheduling. Modeling the network traffic patterns of multiplexed SCADA streams using Deterministic Finite Automata (DFA) for anomaly detection typically produces a very large DFA, and a high false-alarm rate...
متن کاملAdapting Bro into SCADA: Building Specification-based Intrusion Detection System for DNP3 Protocol
Modern SCADA systems are increasingly adopting Internet technology to control industry processes. With their security vulnerabilities exposed to public networks, an attacker is able to penetrate into these control systems to put remote facilities in danger. To detect such attacks, SCADA systems require an intrusion detection technique that can monitor network traffic based on proprietary networ...
متن کاملUsing a Specification-based Intrusion Detection System to Extend the DNP3 Protocol with Security Functionalities
Modern SCADA systems are increasingly adopting Internet technologies to control distributed industrial assets. As proprietary communication protocols are increasingly being used over public networks without efficient protection mechanisms, it is increasingly easier for attackers to penetrate into the communication networks of companies that operate electrical power grids, water plants, and othe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JDFSL
دوره 9 شماره
صفحات -
تاریخ انتشار 2014