Needle guides enhance tissue adequacy and safety of ultrasound-guided renal biopsies

نویسندگان

  • Namrata S. Rao
  • Abhilash Chandra
چکیده

Background Needle guides have recently come into use for ultrasound-guided percutaneous renal biopsies; however, it is not yet clear if the use of needle guides leads to decreased post-biopsy complication rates and improved tissue yields. Thus, we conducted a retrospective single center study comparing biopsy yield, adequacy, and rates of complications before and after utilization of a needle guide device. Methods A retrospective analysis was performed on all native kidney biopsies performed before and after June 2015 corresponding to the start of needle guide use. All biopsies in the latter period of the study were performed by a single operator. We compared clinical characteristics, indications, type of investigation, tissue yield, adequacy of procedure, and rates of major and minor complications. Results A total of 343 biopsies were analyzed, 140 in the pre-needle guide use period (Period I) and 203 in the needle guide use period (Period II). Biopsy yields were similar, irrespective of the use of needle guides. Tissue adequacy was better in Period II (93.7% vs. 84%, P < 0.001, with respect to pathologist-reported inconclusive biopsies. There were no differences in terms of major complications (1.7%) for the two periods; however, the rate of minor complications (8.4%) was significantly reduced in Period II (P = 0.006). According to multiple logistic regression analysis, not using a needle guide (odds ratio, 3.70; P < 0.001) along with low hemoglobin level, higher pre-dialysis serum creatinine level, and high urinary red blood cell count were significant predictors of biopsy complications. Conclusion Use of a needle guide improves biopsy adequacy and is associated with reduced rates of minor complications in native renal biopsies. Therefore, needle guides may be recommended in percutaneous renal biopsies, especially when transitioning to single-operator performed procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum to: Post renal biopsy complication rate and diagnostic yield comparing hands free (ultrasound-assisted) and ultrasound-guided biopsy techniques of renal allografts and native kidneys

BACKGROUND Real time ultrasound guided percutaneous kidney biopsy has become the standard procedure to assess the pathology of native kidneys and renal transplants. No specific technique has shown to be totally free of post biopsy bleeding complications. Few Studies have looked at the rates of post biopsy bleeding complications comparing different needle size, post biopsy haematoma size, or cli...

متن کامل

Post renal biopsy complication rate and diagnostic yield comparing hands free (ultrasound-assisted) and ultrasound-guided biopsy techniques of renal allografts and native kidneys

Background: Real time ultrasound guided percutaneous kidney biopsy has become the standard procedure to assess the pathology of native kidneys and renal transplants. No specific technique has shown to be totally free of post biopsy bleeding complications. Few Studies have looked at the rates of post biopsy bleeding complications comparing different needle size, post biopsy haematoma size, or cl...

متن کامل

Safety and tissue yield for percutaneous native kidney biopsy according to practitioner and ultrasound technique

BACKGROUND Although percutaneous renal biopsy remains an essential tool in the diagnosis and treatment of renal diseases, in recent times the traditional procedure of nephrologists has been performed by non-nephrologists rather than nephrologists at many institutions. The present study assessed the safety and adequacy of tissue yield during percutaneous renal biopsy according to practitioners a...

متن کامل

Safety and Adequacy of Percutaneous Biopsies in Pediatric Orthotopic Kidney Transplantation

BACKGROUND The gold standard for investigating the cause of renal graft dysfunction is renal biopsy. However, as this procedure is invasive and has inherent risks, its safety must be established. OBJECTIVE To determine the safety of percutaneous renal biopsy in pediatric orthotopic renal transplantation. METHODS Percutaneous renal biopsies performed on pediatric orthotopic renal transplants...

متن کامل

بررسی نمونه‌های آسیب‌شناسی حاصل از بیوپسی سوزنی با هدایت سی‌تی‌اسکن در ضایعات قفسه سینه بیماران مراجعه‌کننده به بخش پاتولوژی بیمارستان شهید صدوقی یزد

Introduction: Despite the popularity of needle biopsy for obtaining tissue samples in several solid organs, its use in thoracic lesions has been very restricted in some hospitals. This study intended to investigate the CT-Guided transthoracic core needle biopsy specimens in Yazd Shahid Sadoughi hospital during 2001- 2010. Methods: This is a retrospective cross- sectional study conducted on pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2018