Pinhole versus parallel-hole collimators for parathyroid imaging: an intraindividual comparison.

نویسندگان

  • Maria B Tomas
  • Paul V Pugliese
  • Gene G Tronco
  • Charito Love
  • Christopher J Palestro
  • Kenneth J Nichols
چکیده

UNLABELLED This study was undertaken to determine the effects of collimators on the accuracy of preoperative sestamibi parathyroid imaging of the neck. METHODS Forty-nine patients with primary hyperparathyroidism underwent preoperative (99m)Tc-sestamibi parathyroid imaging. The protocol included early and late pinhole and parallel-hole imaging. One experienced nuclear physician, without knowledge of other test results or final diagnoses, interpreted studies. For both pinhole and parallel-hole images, focally increased sestamibi accumulation outside the normal tracer biodistribution that persisted or increased in intensity from early to late images was interpreted as positive for a parathyroid lesion. Final diagnoses were operatively confirmed in all patients. RESULTS Fifty-four parathyroid lesions were resected from the 49 patients. Forty-five patients had single-gland disease. Four patients had multigland disease: 3 had 2 lesions and 1 had 3 lesions. Median lesion weight was 840 mg. Pinhole imaging was significantly more sensitive than parallel-hole imaging (89% vs. 56%; P = 0.0003) for all 54 lesions. Specificity did not significantly differ between pinhole and parallel-hole imaging (93% vs. 96%, P = 0.29). Pinhole imaging was significantly more sensitive than parallel-hole imaging for lesions above (100% vs. 68%, P = 0.003) and below (77% vs. 42%, P = 0.03) the median weight and for single-gland disease (96% vs. 67%, P = 0.001). Pinhole imaging also was more sensitive for multigland disease, although the difference was only marginally significant (55% vs. 0%, P = 0.037). CONCLUSION Because sensitivity is significantly higher, sestamibi parathyroid imaging of the neck should be performed with a pinhole collimator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved delineation of parathyroid lesions in patients with chronic renal failure using magnified pinhole imaging.

UNLABELLED (99m)Tc-sestamibi dual-phase scintigraphy is currently established for parathyroid localization. However, the imaging technique is not standardized, and the role of the pinhole collimator, especially, is not fully recognized in the imaging protocol. The aim of this study was to check whether the use of a pinhole collimator in parathyroid scintigraphy would enhance lesion detectabilit...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Yttrium-90-labeled microsphere tracking during liver selective internal radiotherapy by bremsstrahlung pinhole SPECT: feasibility study and evaluation in an abdominal phantom

BACKGROUND The purpose of the study is to evaluate whether a pinhole collimator is better adapted to bremsstrahlung single photon emission computed tomography [SPECT] than parallel-hole collimators and in the affirmative, to evaluate whether pinhole bremsstrahlung SPECT, including a simple model of the scatter inside the patient, could provide a fast dosimetry assessment in liver selective inte...

متن کامل

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Tomographic image quality of rotating slat versus parallel hole-collimated SPECT.

Parallel and converging hole collimators are most frequently used in nuclear medicine. Less common is the use of rotating slat collimators for single photon emission computed tomography (SPECT). The higher photon collection efficiency, inherent to the geometry of rotating slat collimators, results in much lower noise in the data. However, plane integrals contain spatial information in only one ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2008