Comparison of second-generation stents for application in the superficial femoral artery: an in vitro evaluation focusing on stent design.

نویسندگان

  • Stefan Müller-Hülsbeck
  • Philipp J Schäfer
  • Nikolas Charalambous
  • Hiroshi Yagi
  • Martin Heller
  • Thomas Jahnke
چکیده

PURPOSE To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design comparison; the strain during stent movement was calculated for bending, compression, and torsion. Additional mechanical fatigue tests for bending (70°), compression (40%), and torsion (twisted counterclockwise by 180°) were performed up to 650,000 cycles or until a fracture was observed. RESULTS The FEA bending test showed that only the Misago, LifeStent, and Absolute stents presented no zones of high strain; in the torsion test, the Smart stent also had no zones of high strain. Macroscopic evaluation after mechanical bending indicated that the LifeStent performed the best (no stent fracture after 650,000 cycles). Misago and Absolute stents showed fractures at 536,000 cycles and 456,667 cycles, respectively (range 320,000-650,000 cycles). After compression and torsion testing, Misago showed no stent fracture after 650,000 cycles. The worst performing stent was Luminexx during all test cycles. CONCLUSION The 7 SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. Differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

بررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385

Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...

متن کامل

Acute stent malfunction in a calcified lesion

Stent fracture is an emerging complication of coronary stenting. Stent fractures were originally reported in the superficial femoral arteries but have since been reported in almost all vascular sites. They are the result of the complex interplay among stent design, the stented segment, plaque morphology, deployment technique, including forceful exaggerated motion in the atrioventricular groove ...

متن کامل

Drug-Eluting Stents in the Superficial Femoral Artery

1435 When coronary drug-eluting stents (DES) burst onto the scene with the publication of the remarkable results from the Randomized Study with the Sirolimus-Coated BX Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions (RAVEL) trial, the practice of interventional cardiology changed forever. Large-scale randomized trials confirmed the supe...

متن کامل

Cost-effectiveness of superficial femoral artery endovascular interventions in the UK and Germany: a modelling study

OBJECTIVES To assess the lifetime costs and cost-effectiveness of 5 endovascular interventions to treat superficial femoral arterial disease. DESIGN A model-based health economic evaluation. An existing decision analytical model was used, with updated effectiveness data taken from the literature, and updated costs based on purchasing prices. SETTING UK and German healthcare perspectives wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2010