Body composition analyses by air displacement plethysmography in adults ranging from normal weight to extremely obese

نویسندگان

  • Kazanna C. Hames
  • Steven J. Anthony
  • John C. Thornton
  • Dympna Gallagher
  • Bret H. Goodpaster
چکیده

OBJECTIVE To compare body composition parameters estimated by air displacement plethysmography (ADP) to dual X-ray absorptiometry (DXA) in body mass index (BMI) classifications that include extremely obese (BMI ≥ 40.0 kg/m(2) ), and to examine if differences between analyses were influenced by BMI. METHODS Fat-free mass (FFM, kg), fat mass (FM, kg), and body fat (BF, %) were analyzed with both technologies. RESULTS All outcome measures of ADP and DXA were highly correlated (r ≥ 0.95, P < 0.001 for FFM, FM, and BF), but Bland-Altman analyses revealed significant bias (P < 0.01 for all). ADP estimated greater FFM and lower FM and BF (P < 0.01 for all). BMI explained 27% of the variance in differences between FFM measurements (P < 0.001), and 37 and 33% of the variances in differences between FM and BF measurements, respectively (P < 0.001 for both). Within normal weight and overweight classifications, ADP estimated greater FFM and lower FM and BF (P < 0.001 for all), but the opposite occurred within the extremely obese classification; ADP estimated lower FFM and greater FM and BF (P < 0.05 for all). CONCLUSIONS Body composition analyses by the two technologies were strongly congruent, but systematically different and influenced by BMI. Caution should be taken when utilizing ADP to estimate body composition parameters over a wide range of BMI classifications that include extremely obese.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals

BACKGROUND Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate...

متن کامل

Interaction of clothing and body mass index affects validity of air-displacement plethysmography in adults.

OBJECTIVE We determined the effect of clothing type on the validity of air-displacement plethysmography (ADP) to estimate percentage of body fat (%BF) and ascertain if these effects differ by body mass index (BMI). METHODS The %BF by dual x-ray absorptiometry (DXA) and %BF, density, and body volume by ADP were assessed in 132 healthy adults classified by normal (N; 18.5-24.9 kg/m2), overweigh...

متن کامل

Title: Air displacement plethysmography for estimating body composition changes with weight loss in middle-aged Japanese men Short running head: Body composition change by air displacement method

Aim: To examine the degree to which air displacement plethysmography (ADP) can track body composition changes in response to weight loss in obese Japanese men. Method: Fifty men, aged 30–65 yr, with a mean body mass index of 30 kg/m, received a 3-month weight-loss program. Percentage of fat mass (%FM) was determined by dual energy X-ray absorptiometry (DXA) and ADP at baseline and month 3. Resu...

متن کامل

Body composition measurement in severe obesity.

PURPOSE OF REVIEW Severe obesity is accompanied by large increases in fat mass and alterations in the composition of fat free mass, in particular total body water and its extracellular compartment. The physical size limitations imposed by severe obesity, and variations in body composition from that of normal weight, pose tremendous challenges to the measurement of body composition. This review ...

متن کامل

Body composition assessment in extreme obesity and after massive weight loss induced by gastric bypass surgery.

Body composition methods were examined in 20 women [body mass index (BMI) 48.7 +/- 8.8 kg/m(2)] before and after weight loss [-44.8 +/- 14.6 (SD) kg] after gastric bypass (GBP) surgery. The reference method, a three-compartment (3C) model using body density by air displacement plethysmography and total body water (TBW) by H(2)18O dilution (3C-H(2)18O), showed a decrease in percent body fat (%BF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2014