Evaluation of an innovative plastic cube phantom designed to improve the efficiency of accelerator QA
نویسندگان
چکیده
A new cubic phantom was designed to improve the efficiency on the QA measurement of accelerator. It has a variety of applications, such as dose constancy check, depth dose verifications, and symmetry and flatness evaluations. In particular, this new design makes it much easier to perform the check on output constancy vs. gantry angles as a cylindrical ion chamber positioned at the center of the phantom. The reproducibility of the setup using this phantom has been investigated. The charge effect of the phantom is found to be insignificant. It also reduces the monthly dosimetric QA time spent on a typical multimodality accelerator by approximately 40%.
منابع مشابه
Comparison between two different methods used for IMRT plans QA of Prostate cancer
Introduction: The aim of this study is evaluation of two Quality Assurance methods in sliding window IMRT technique and Determination of gamma index in both methods Materials and Methods: In this study two tools named" Delta4" phantom and " Epiqa" software has been used to perform QA on the treatment plan before the actual treatment by Varian linear acceler...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملEnhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom.
Tomotherapy is an image-guided, intensity-modulated radiation therapy system that delivers highly conformal dose distributions in a helical fashion. This system is also capable of acquiring megavoltage computed-tomography images and registering them to the planning kVCT images for accurate target localization. Quality assurance (QA) of this device is time intensive, but can be expedited by impr...
متن کاملEvaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy
Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...
متن کامل