A respiratory gas exchange simulator for routine calibration in metabolic studies.

نویسندگان

  • A Huszczuk
  • B J Whipp
  • K Wasserman
چکیده

We have developed a method for simulating respiratory gas exchange for on-line calibration of metabolic measurement systems. It utilizes a pump which intakes a mixture of atmospheric air and a known flow of precision-analysed calibration gas (21% CO2, 79% N2). It expels the resulting mixture with flow wave form and profiles of gas concentration which closely resemble those of normal expiration. Control of the calibration mixture's inflow allows the investigator to set any desired metabolic rate regardless of the minute ventilatory rate. This separation of metabolic from ventilatory rates provides a stringent test of the computational performance of the respiratory gas exchange measurement systems. The apparatus can reproduce any range of respiratory and metabolic performance (currently ranging from 0.2-5 l.min-1 O2 uptake and CO2 output) with accuracy +/- 2%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Accurate Metabolic Simulator for Indirect Calorimetry System Validation

A metabolic simulator capable of simulation of respiratory oxygen consumption (VO2) and carbon dioxide production (VCO2) for validation of indirect calorimetry systems is described. The metabolic simulator adds/removes respiratory gases by way of mass flow controllers to/from a physiologically realistic lung simulator (Michigan Instruments Inc. Training/Test Lung). The metabolic simulator and M...

متن کامل

Gas analyzer's drift leads to systematic error in maximal oxygen uptake and maximal respiratory exchange ratio determination

The aim was to examine the drift in the measurements of fractional concentration of oxygen (FO2) and carbon dioxide (FCO2) of a Nafion-using metabolic cart during incremental maximal exercise in 18 young and 12 elderly males, and to propose a way in which the drift can be corrected. The drift was verified by comparing the pre-test calibration values with the immediate post-test verification val...

متن کامل

Feasibility of a laboratory-based accelerometer calibration protocol for children with intellectual disabilities

BACKGROUND Accelerometry has not been calibrated for the estimation of physical activity in children with intellectual disabilities (ID), raising questions regarding the validity of interpreting accelerometer data in this population. Various protocols and criterion measures have been used in calibration studies involving typically developing (TD) children; however, the suitability of these acti...

متن کامل

Metabolic rate and respiratory gas-exchange patterns in tenebrionid beetles from the Negev Highlands, Israel.

This study correlates the pattern of external gas exchange with the diel activity of nine species of tenebrionid beetle from the Negev Desert, Israel. The study species are active throughout the summer months when daytime temperatures are high and no rain falls. There were no differences in standard metabolic rate, determined by flow-through respirometry, among the nine species. All the nocturn...

متن کامل

Indirect calorimetry in humans: a postcalorimetric evaluation procedure for correction of metabolic monitor variability.

BACKGROUND Indirect calorimetry (IC) with metabolic monitors is widely used for noninvasive assessment of energy expenditure and macronutrient oxidation in health and disease. OBJECTIVE To overcome deficiencies in validity and reliability of metabolic monitors, we established a procedure that allowed correction for monitor-specific deviations. DESIGN Randomized comparative IC (canopy mode) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 1990